Position: Home > > Physical property test > Surface physical property test > Chemical adsorption apparatus > VDSorb-90i basic chemisorber for energy field

VDSorb-90i basic chemisorber for energy field

Product ID:WBhxxf014

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberVDSorb-90i
    Brand NameQUZHOUWODE
    Payment TermsTT,PAYPAL
    VDSorb-90i basic chemisorber
     
    Introduction:
    VDSORB-90i is a basic chemisorber that can realize TPD/TPR/TPO and other experiments. It has the characteristics of small size, high sensitivity, simple operation and high cost performance. It is very suitable for the qualitative analysis of catalysts. VDSorb-90BS is an economical chemisorption instrument. On the premise of ensuring its performance, we have removed other redundant functions and simplified the instrument shape, so that the instrument can perform the qualitative analysis of temperature-programmed chemisorption excellently.
    Features:
    1. "Y" type reactor
    We customized a "Y" type straight-tube reactor for the reactor. Using the "Y" sample loading feature, the relative position of the catalyst and the reactor can be accurately positioned, ensuring the consistency of each sample loading position.
    2. Horizontal integral reactor
    The reaction furnace adopts a horizontal integral design, which greatly facilitates the disassembly and assembly of the sample tube by engineers. With the strong air cooling technology, the problem of long heat dissipation time of the integral furnace is effectively solved, and the instrument works well. .
    3. Groundbreaking sensor technology
    Thermal Conductivity Detector (TCD) is an important sensor in the system. For this reason, we use a specific technology to meet the needs of high-demand detection: Micro-upgrade the volume of the inner cavity, which greatly improves the detection sensitivity; The inner wall of the cell adopts special inertness The material coating greatly reduces the adsorption probability of trace gases on the inner wall of the cell; SPID (SMART-PID) high-precision fuzzy control algorithm is optimized, so that the temperature accuracy of the TCD cell body is <±0.01; 0.5µV~200mV micro-signal linear amplification, real reduction reaction characteristics.
    4. Flow Control
    The accuracy and stability of gas flow control directly affects the stability of the signal. We equip the instrument with a high-precision mass flow controller to ensure the stability of the system.
    5. Program temperature
    The key technology of temperature programming is whether the heating curve can be flat. Through the optimization of the reaction furnace and SPID temperature control technology, we have achieved a smooth temperature rise from RT to 1100 °C to ensure the authenticity and reliability of the experimental results.
    6. VDSorb-Station Workstation
    We simplified the VDSorb-Staion workstation, removed redundant functions, and made the software operation simple and convenient on the basis of satisfying instrument control.
    Technical parameter:
     Repeatability: <0.5%
    Amount of catalyst: 5200mg
    Reaction furnace temperature: RT1100
    Reactor control accuracy: <0.1
    Reaction furnace heating rate: 0100/min (RT500)
                          050/min500800
                          030/min8001100
    Reaction furnace heating curve smoothness: <0.3%
    Gas flow range: 0100sccm (extendable)
    Flow Accuracy: <0.5%F.S.
     Detector Baseline Noise: <30μA
    Detector baseline drift: <50μA/30min
    Detector temperature range: RT250
    Detector temperature control accuracy: <0.01
     Cold trap temperature range: -196RT
  • Introduction:
    VDSORB-90i is a basic chemisorber that can realize TPD/TPR/TPO and other experiments. It has the characteristics of small size, high sensitivity, simple operation and high cost performance. It is very suitable for the qualitative analysis of catalysts. VDSorb-90BS is an economical chemisorption instrument. On the premise of ensuring its performance, we have removed other redundant functions and simplified the instrument shape, so that the instrument can perform the qualitative analysis of temperature-programmed chemisorption excellently.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com