Brief introduction: ZCT - type B comprehensive thermal analyzer system combines DTA and TG, can be in the same test conditions, studies the quality change and temperature change of the sample. Comprehensive thermal analyzer used in most materials, including plastic, rubber, synthetic resin, fiber, coating, grease ceramics, cement, glass, refractory materials, fuel, medicine, food, refractory materials, etc. Features: 1. The whole machine integration, reasonable structure, stable mechanical performance 2. Using high integration of words acquisition and control system, a high degree of automation 3. The vertical structure, the top sample loading, easy to operate, not easy to damage, to prevent sample contamination. 4. A variety of heating furnace, apply to more fields, the user can change, simple and convenient 5. Excellent extensibility, but with infrared analyzer (FTIR), mass spectrometer (MS), gas chromatograph (GC) analysis 6. Data collection, storage, amplification, smooth, drawing translation, screen display and result report: differential thermal curve, weight curve, the temperature curve, differential curve smoothing. 7. DTA analysis, extrapolation starting temperature, peak temperature and peak area calculation, K value, enthalpy, etc. 8. TG weightlessness percentage: weightlessness beginning temperature and final temperature, weightlessness biggest point temperature is calculated. 9. TG curve of the temperature of the arbitrary point of weightlessness the arbitrary point and the percentage of display. Technical parameters: Temperature: room temperature - 1450 degrees Heating rate: 0.1 ~ 100 ℃ / min Cooling rate: 0.1 ~ 40 ℃ / min The temperature sensitivity: 0.1 ℃ Differential thermal range: plus or minus 10 ~ + 1000 uv Differential thermal sensitivity: 0.01 u V Differential thermal accuracy: 0.1 u V Software simulation of DSC: + 1 ~ + 100 mw DSC sensitivity: 0.1 uW Thermogravimetric range: 1-200 mg, change of up to 5 g support bar Thermogravimetric sensitivity: 0.1 ug Thermogravimetric accuracy: 1 ug Thermogravimetric noise: < 1 ug Thermogravimetric differential range: 1-100 mg/min Automatic zero range: 0 ~ 999 mg Vacuum: 2.66 X10-2 pa
Brief introduction: ZCT - type B comprehensive thermal analyzer system combines DTA and TG, can be in the same test conditions, studies the quality change and temperature change of the sample. Comprehensive thermal analyzer used in most materials, including plastic, rubber, synthetic resin, fiber, coating, grease ceramics, cement, glass, refractory materials, fuel, medicine, food, refractory materials, etc.