Features: 1. Heat flow DSC data acquisition mode, draw energy and temperature curve. 2. The user was able to use standard sample accuracy of temperature, energy, and heavy. 3. The atmosphere control system using mass flow controller, three-way voltage regulator, steady flow gas can automatic switch in the experimental process, high precision, good repeatability, fast response speed (can customize the atmosphere of the resistance to all kinds of corrosive gas control system). 4. From the trace sample to large dose samples can satisfy (replacement support bar, maximum sample up to 5 g). Can meet the test requirements of various kinds of samples under different conditions. 5. The whole measurement process automatically, automatic drawing, rich software function can complete DTA, TG, DTG, DTTG and conventional data 6. In the process of the system to collect sample, can at any time the screenshot, according to the size of the output signal automatic transformation range. Large screen LCD, real-time display of the instrument condition and data, two sets of temperature measuring thermocouple, a set of galvanic real-time display temperature (regardless of the heating furnace work or not) another set of galvanic couple sample temperature display work. 8. The user gives a calculation formula and calculation method, our factory can provide the corresponding software development products. 9. Independent research and development of constant temperature controller; Constant temperature gas chromatography and mass spectrometry connected head; Constant temperature; Can fully guarantee the tar and various kinds of secondary reaction gas detection. Technical indicators: 1. The DSC data DSC measurement range 1 mw ~ 200 mw DSC precision is 0.1 2. The temperature data Temperature range: HCT - 1 at room temperature to 1150 ℃ HCT - 2: at room temperature to 1250 ℃ HCT - 3: at room temperature to 1450 ℃ HCT - 4: at room temperature to 1550 ℃ Plus or minus 0.1 ℃ temperature accuracy The heating rate of 0.1 ℃ / min to 100 ℃ / min 3. Balance data Measuring range 1 mg to 200 mg up to 5 g change the support bar The resolution (including 0.1 g Thermogravimetric noise < 0.1 (including g Vacuum (instrument itself has a vacuum seal measures) selected after vacuum unit can reach 2.66 x 10-2 pa Atmosphere control system The mass flow controller (resistance can be customized various corrosive gas atmosphere control system) Constant temperature controller; Constant temperature gas chromatography and mass spectrometry connected head; Constant temperature zone (optional) Constant temperature range: room temperature - 400 ℃ 4. The differential thermal data The measuring range of 10 v, 2000 v The resolution is 0.01 v DTA Crucible crucible standard configuration: ceramic crucible 0.06 ml and 0.12 ml
Features: 1. Heat flow DSC data acquisition mode, draw energy and temperature curve. 2. The user was able to use standard sample accuracy of temperature, energy, and heavy. 3. The atmosphere control system using mass flow controller, three-way voltage regulator, steady flow gas can automatic switch in the experimental process, high precision, good repeatability, fast response speed (can customize the atmosphere of the resistance to all kinds of corrosive gas control system).