Position: Home > > Analytical instruments > Spectrometry > Fiber optic spectrometer > YSM-8104-07 Cooled Array Spectrometer

YSM-8104-07 Cooled Array Spectrometer

Product ID:FGgx050

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberYSM-8104-07
    Brand NameYIXIZHINENG
    Payment TermsTT,PAYPAL
    YSM-8104-07 Cooled Array Spectrometer
    Introduction:
    The YSM-8104 series high-performance TE refrigeration spectrometer adopts Hamamatsu's advanced backlit thin film refrigeration type area array CCD, providing two versions: 1024 pixel and 2048 pixel, with excellent scientific research level sensitivity. Its optimized low noise circuit system uses an 18 bit A/D converter, combined with an excellent CT optical mechanical structure, greatly improving the signal-to-noise ratio, sensitivity, and thermal stability of the spectrometer. It is very suitable for measuring weak spectral signals such as Raman and fluorescence. The YSM-8104 series adopts a replaceable slit design, and a spectrometer can be configured with multiple slits of different widths to meet the spectral measurement needs of different resolutions and sensitivities. Its wavelength range and optical resolution can be independently configured, supporting secondary development, trigger control, and deep customization of the spectrometer according to your needs.
    The YSM-8104-07 series spectrometer uses the Hamamatsu S7031-1006s series 1024x58 pixel backlit cooling array CCD, with a pixel size of 24 µ m × 24 µ m, with excellent sensitivity.
    Features:
    1. Hamamatsu backlight thin plate refrigeration type area array CCD, signal-to-noise ratio 1000:1
    2. 18 bit A/D conversion, dynamic range 100000:1 (typical value)
    3. Replaceable slit design, 5 µ m, 10 µ m, 25 µ m, 50 µ m, 100 µ m, 200 µ m
    Available in two versions: 4.1024 pixels and 2048 pixels
    5. Pixel size can reach 24 µ m × 24 µ m
    6. Cross asymmetric C-T optical path structure, interference filter to eliminate secondary diffraction
    7. SMA905 fiber optic interface, easy to connect with other devices through fiber optics
    8. Customizable wavelength range and optical resolution
    9. USB 2.0 data transmission and power supply, supporting RS232/RS422 communication, and supporting multiple triggering methods
    10. The software is powerful and can automatically calculate peak wavelength and bandwidth functions
    11. Support for secondary development and deep customization
    Technical parameters:
    Size: 190mm × 120mm × 66mm
    Weight: 1.5 Kg
    Detector: Hamamatsu S7031-1006s Backlit Thin Plate Refrigerated Area Array CCD
    one thousand and twenty-four × 58 pixels, pixel size: 24 µ m × 24 µ m
    Wavelength response: 200nm-1100nm
    A/D: 18bit
    Signal to noise ratio: 1000:1
    Dynamic range: 100000:1
    Integration time: 8ms-3600s
    Communication interface: USB2.0 (12Mbps)
    RS232 (115200bps)
    Minimum cooling temperature: 30 (-10 ) below ambient temperature
    Power supply: 5 VDC, 2A
    Spectral range: determined by specific grating
    Resolution: optimal~0.3nm (determined by both grating and slit)
    Trigger method: software trigger, hardware trigger, synchronous trigger
    Operating system: Win XP, Win7, Win 8, Win10, Win11

  • Introduction:
    The YSM-8104 series high-performance TE refrigeration spectrometer adopts Hamamatsu's advanced backlit thin film refrigeration type area array CCD, providing two versions: 1024 pixel and 2048 pixel, with excellent scientific research level sensitivity. Its optimized low noise circuit system uses an 18 bit A/D converter, combined with an excellent CT optical mechanical structure, greatly improving the signal-to-noise ratio, sensitivity, and thermal stability of the spectrometer. It is very suitable for measuring weak spectral signals such as Raman and fluorescence. The YSM-8104 series adopts a replaceable slit design, and a spectrometer can be configured with multiple slits of different widths to meet the spectral measurement needs of different resolutions and sensitivities. Its wavelength range and optical resolution can be independently configured, supporting secondary development, trigger control, and deep customization of the spectrometer according to your needs.
    The YSM-8104-07 series spectrometer uses the Hamamatsu S7031-1006s series 1024x58 pixel backlit cooling array CCD, with a pixel size of 24 µ m × 24 µ m, with excellent sensitivity.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com