YND-BM4 multi-channel differential scanning calorimeter for Material change research

Product ID:WLcs018

Price: Please inquire PDF Format
Supply Ability:20SETS/MONTH
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberYND-BM4
    Brand NameSHYN
    Payment TermsT/T, paypal
    Introduction:
    YND-BM4 multi-channel differential scanning calorimeter touch screen instrument, can do 4 samples in a single time;
    Comply with, but not limited to, the following national standards: GB/T 19466.3-2009/ISO 11357-3:1999 Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induced temperature (dynamic OIT) in the oxidation induction period; GB/T 19466.2 - 2004/ISO 11357-2:1999 Part 2: Determination of glass transition temperature; GB/T 19466.3-2004/ISO 11357-3:1999 Part 3: Determination of melting and crystallization temperatures and enthalpy.
    Features:
    1. Industrial-grade wide-screen touch structure, showing rich information, including set temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, various switch states, and flow return to zero.
    2. The furnace body is heated by electric heating wire, and the furnace body is cooled by electronic semiconductor refrigeration, which has compact structure and small volume. No need for external cooling source and cumbersome refrigeration system, heating and cooling rate
    Fast, the minimum cooling temperature can reach -40 degrees.
    3, USB communication interface, strong versatility, reliable signal without interruption, support self-recovery connection function.
    4. The structure of the furnace body is compact, and the temperature rise and fall rate can be adjusted arbitrarily.
    5. The installation process is improved, and all mechanical fixing methods are adopted to completely avoid the contamination of the internal heat of the furnace body by the differential heat signal.
    6, dual temperature probe to ensure high repeatability of sample temperature measurement. A temperature probe is installed on the wall of the furnace for PID control of the temperature of the entire furnace, but due to the thermal inertia of the temperature,
    There is a certain deviation in the temperature on the sample, and the deviation is different in spring, summer, autumn and winter. Therefore, the temperature is measured and temperature controlled by a single temperature probe, whether it is a differential heat signal or a temperature signal, the error is better than
    Larger; the instrument has a temperature probe installed at the bottom of the sample to measure the true temperature of the sample, and we use our special temperature control technology to control the temperature of the furnace wall to make the sample temperature
    The set temperature is reached.
    7. The digital gas mass flow meter automatically switches the two-way gas flow, and the switching speed is fast and the stabilization time is short.
    8. Standard samples are standard to facilitate the customer to adjust the constant temperature coefficient.
    9. The software adapts to the computer screen of each resolution, and the software automatically adjusts the display mode of each curve according to the size of the computer screen. Support notebook, desktop, support WIN XP, WIN 7, WIN 8
    WIN 10 all operating systems.
    10. Support user self-programming program to realize full automation of measurement steps. The software provides dozens of instructions, and users can flexibly combine and save each instruction according to their own measurement steps. Complex operation
    This is simplified into a one-button operation.
    11. High-grade aluminum alloy instrument box with high-pressure elastic foam packaging, which can be carried and moved by customers.
    12, new furnace structure design, support for simultaneous measurement of 4 samples
    Technical Parameters:
    temperature range Room temperature - 500 degrees
    Temperature accuracy 0.01 ° C (standard metal sample)
    Heating rate 0.1-80 ° C / min
    Temperature control method Heating, constant temperature (fully controlled
    DSC range 0-±500mw
    DSC noise 0.001μw
    DSC resolution 0.001μw
    DSC accuracy 0.001μw
    DSC sensitivity 0.001μw
    output method Computer and printer
    Working power supply AC220V 50HZ or custom
    Atmosphere control gas Nitrogen, oxygen (automatic control of the instrument)
    Gas flow 0—200ml/min
    gas pressure 0.2mpa
    Gas flow accuracy 0.2ml/min
    Optional equipment Aluminum crucible diameter 6.6*3
    Parameter standard With standard samples (indium, tin, zinc), users can correct temperature and enthusiasm
    Data interface Standard USB interface
    Display method 24bit color, 7 inch LED touch screen display
     
  • Introduction:
    YND-BM4 multi-channel differential scanning calorimeter touch screen instrument, can do 4 samples in a single time;
    Comply with, but not limited to, the following national standards: GB/T 19466.3-2009/ISO 11357-3:1999 Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induced temperature (dynamic OIT) in the oxidation induction period; GB/T 19466.2 - 2004/ISO 11357-2:1999 Part 2: Determination of glass transition temperature; GB/T 19466.3-2004/ISO 11357-3:1999 Part 3: Determination of melting and crystallization temperatures and enthalpy.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com