DSC-600 Differential Scanning Calorimeter Introduction: Differential Scanning Calorimetry (DSC), as a classic thermal analysis method for thermal effects under controllable program temperature, has been widely used in various fields of materials and chemistry, including research and development, process optimization, quality control, and failure analysis. By using DSC method, we can study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphic phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats. Instrument purpose: To measure physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, curing/crosslinking, oxidation induction period, etc. characteristic: 1. The new fully enclosed metal furnace body design structure greatly improves sensitivity, resolution, and baseline stability. 2. Adopting alloy sensors, which are more resistant to corrosion and oxidation, and have high sensor sensitivity. 3. Adopting Cortex-M3 core ARM controller, the processing speed is faster and the temperature control is more accurate. 4. Adopting USB bidirectional communication to achieve intelligent operation. 5. Adopt a 7-inch 24 bit full-color LCD touch screen to display the status and data of the instrument in real time. 6. Intelligent software design, instrument automatic drawing throughout the process, software can achieve various data processing, such as enthalpy calculation, glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc. Technical parameters: DSC range: 0 to ± 500mW Temperature range: Room temperature~600 ℃ Heating rate: 0.1~80 ℃/min Temperature resolution: 0.01 ℃ Temperature repeatability: ± 0.1 ℃ DSC noise: 0.001mW DSC resolution: 0.001mW DSC accuracy: 0.01mW DSC sensitivity: 0.01mW Temperature control method: heating up, constant temperature (fully programmed automatic control) Curve scan: Temperature rise scan Atmosphere control: automatic switching of instruments Gas flow rate: 0-200mL/min Gas pressure: 0.2MPa Display mode: 24 bit color 7-inch LCD touch screen display Data interface: Standard USB interface Parameter standard: equipped with standard substances, with one click calibration function, users can calibrate temperature and enthalpy by themselves Working power supply: AC 220V 50Hz or customized Power: 600W
Introduction: Differential Scanning Calorimetry (DSC), as a classic thermal analysis method for thermal effects under controllable program temperature, has been widely used in various fields of materials and chemistry, including research and development, process optimization, quality control, and failure analysis. By using DSC method, we can study the phase transition of inorganic materials, the melting and crystallization process of polymer materials, the polymorphic phenomenon of drugs, and the solid/liquid phase ratio of foods such as oils and fats. Instrument purpose: To measure physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, curing/crosslinking, oxidation induction period, etc.