DZ-DSC300 Differential Scanning Calorimeter Introduction: DSC measures the relationship between temperature and heat flow related to the thermal transformation inside a material, and has a wide range of applications, especially in material research and development, performance testing, and quality control. Material properties: such as glass transition temperature, cold crystallization, phase transition, melting, crystallization, thermal stability, curing/crosslinking, oxidation induction period, etc., are all areas of DSC research and development. Features: 1. Brand new furnace structure, better resolution and resolution and better baseline stability 2. Parameters can be set to multi-stage heating, constant temperature, cooling 3. The instrument can adopt two-way control (host control, software control), with friendly interface and easy operation 4. Using imported chips, acquisition circuit shielding and anti-interference processing 5. The sensor adopts hot-melt technology instead of traditional spot welding technology, with higher sensitivity Technical parameter: Temperature range: room temperature~600℃ Temperature accuracy: 0.001℃ Temperature fluctuation: ±0.01℃ Heating rate: 0.1~100℃/min Constant temperature time: can be set by yourself Temperature control method: heating, constant temperature, cooling (automatic program control) Scanning mode: heating scan, cooling scan DSC range: 0~±600mW DSC resolution: 0.01uW DSC degree: 0.001mW Working power: AC220V/50Hz or customized Atmosphere control gas: two-way automatic switching (automatic switching of the instrument) Program control: six-stage heating and constant temperature control can be realized, and special parameters can be customized Gas flow: 0-300mL/min (other ranges can be customized) Gas pressure: ≤5MPa Display mode: 24bit color, 7-inch LCD touch screen display Data interface: standard USB interface Parameter standard: Equipped with standard materials (indium, tin, lead), users can calibrate the temperature by themselves Software: with temperature multi-point correction function
Introduction: DSC measures the relationship between temperature and heat flow related to the thermal transformation inside a material, and has a wide range of applications, especially in material research and development, performance testing, and quality control. Material properties: such as glass transition temperature, cold crystallization, phase transition, melting, crystallization, thermal stability, curing/crosslinking, oxidation induction period, etc., are all areas of DSC research and development.