Position: Home > > Physical property test > Thermal analysis instrument > Differential scanning calorimeter > YND-A1 differential scanning calorimeter for Materials Analysis

YND-A1 differential scanning calorimeter for Materials Analysis

Product ID:WLcs012

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberYND-A1
    Brand NameYIMA
    Payment TermsT/T, paypal
    Features:
    1. Oxidation-specific test instrument, the customer a key operation, the software fully automatic operation.
    2. The new sensor sample holder, fully enclosed structure design, to prevent items falling into the furnace to go.
    3. The instrument complies with the requirements of G B / T 19466.3-2009 / ISO 11357-3: 1999, Part 6 Oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT).
    4. Built-in 10-inch large industrial-grade computer, no reprovision of computers, integrated equipment, display information rich, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, a variety of switch states, zero.
    5. The right side of the instrument comes standard with four USB ports, convenient external users mouse, keyboard, printer, U disk and other external devices, user-friendly.
    6. The instrument's internal USB communication interface, relative to the original instrument, more stability, versatility, reliable communication without interruption, support for self-recovery connection.
    7. Digital gas mass flow meter automatically switches two atmosphere flow, switching speed, short stabilization time.
    8. Standard standard sample to facilitate customers to calibrate the constant temperature coefficient.
    9. Pre-install the software, no computer adaptability problems, reduce the replacement of the computer, install the driver caused by the error connection and other issues.
    10. Supports user self-programming, fully automated measurement steps. Software provides dozens of instructions, the user can according to their own measurement steps, flexible combination of the instructions, and save. Complex operation is simplified into a key operation.
    11. Can be stored, operating mode touch screen and mouse button can be used
    Technical Parameters:
    Temperature range: room temperature ~ 500
    Temperature resolution: 0.01
    Heating rate: 0.1 ~ 80 / min
    Temperature control methods: heating, constant temperature (automatic program control)
    DSC range: 0 ~ ± 500mW
    DSC resolution: 0.01 mW
    DSC sensitivity: 0.1mW
    Working power: AC 220V 50Hz or custom
    Atmosphere Control Gas: Nitrogen Oxygen (instrument automatically switches)
    Gas flow: 0-200mL / min
    Gas pressure: 0.2MPa
    Gas flow rate accuracy: 0.2mL / min
    Optional Crucible: Aluminum crucible Φ6.7 * 3mm
    Standard: With standard materials (indium, tin, zinc), the user can correct the temperature and enthalpy
    Data Interface: Standard USB interface (built-in interface, no external connection)
    Display: 10 inch industrial computer touch display, external mouse, keyboard, U disk, printer

  • Features:
    1. Oxidation-specific test instrument, the customer a key operation, the software fully automatic operation.
    2. The new sensor sample holder, fully enclosed structure design, to prevent items falling into the furnace to go.
    3. The instrument complies with the requirements of G B / T 19466.3-2009 / ISO 11357-3: 1999, Part 6 Oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT).
    4. Built-in 10-inch large industrial-grade computer, no reprovision of computers, integrated equipment, display information rich, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, a variety of switch states, zero.
    5. The right side of the instrument comes standard with four USB ports, convenient external users mouse, keyboard, printer, U disk and other external devices, user-friendly.
    6. The instrument's internal USB communication interface, relative to the original instrument, more stability, versatility, reliable communication without interruption, support for self-recovery connection.
    7. Digital gas mass flow meter automatically switches two atmosphere flow, switching speed, short stabilization time.
    8. Standard standard sample to facilitate customers to calibrate the constant temperature coefficient.
    9. Pre-install the software, no computer adaptability problems, reduce the replacement of the computer, install the driver caused by the error connection and other issues.
    10. Supports user self-programming, fully automated measurement steps. Software provides dozens of instructions, the user can according to their own measurement steps, flexible combination of the instructions, and save. Complex operation is simplified into a key operation.
    11. Can be stored, operating mode touch screen and mouse button can be used
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com