Y500-B fluorescence dissolved oxygen sensor for Water quality testing

Product ID:HSCrjy017

Price: Please inquire PDF Format
Supply Ability:200SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberY500-B
    Brand NameYIMA
    Payment TermsT/T, paypal
    Introduction:
    Portable fluorimetric dissolved oxygen sensor, using the world's leading fluorescence life technology. RS485 output, support MODBUS, from maintenance, you can quickly and accurately measure the dissolved oxygen content, built-in temperature sensor, with automatic water temperature compensation. Can provide stable, highly reproducible, highly sensitive results of dissolved oxygen analysis. Determination principle: Fluorescence DO detector is based on the principle of quenching of active fluorescence in a specific substance in physics. The blue light emitted by a light-emitting diode (LED) shines on the fluorescent substance on the inner surface of the fluorescent cap. The fluorescent substance on the inner surface receives the excitation and emits red light. By detecting the phase difference between the red light and the blue light and calibrating with the internal calibration Value comparison, which calculates the concentration of oxygen molecules, after the temperature and pressure automatically output the final output value.
    Features
    1 digital sensor, RS485 output, support MODBUS
    2 no film, no electrolyte, no interference, no frequent calibration
    3 does not consume oxygen, there is no flow rate limit
    4 built-in temperature sensor, automatic temperature compensation
    Specifications:
    Range: 0 ~ 20mg / L or 0 ~ 200% saturation
    Accuracy: 1%
    Response time: 10 sec
    Sensor drift: <1% per year
    Temperature range: 0 ~ 50
    Temperature accuracy: ± 0.2
    Protection class: IP68
    Maximum operating pressure: 6bar
    Sensor Interface: Support RS-485, MODBUS protocol
    Power Information: DC 6 ~ 12V, current <50mA
    Sensor size: Φ16 * 180 mm
    Probe cable length: 5m, the other customers optional 10m, 15m and 30m cable
    Calibration: One or two calibration
    Fluorescent cap life: to ensure the use of one year (under normal use)
    Sensor material: POM or stainless steel

  • Introduction:
    Portable fluorimetric dissolved oxygen sensor, using the world's leading fluorescence life technology. RS485 output, support MODBUS, from maintenance, you can quickly and accurately measure the dissolved oxygen content, built-in temperature sensor, with automatic water temperature compensation. Can provide stable, highly reproducible, highly sensitive results of dissolved oxygen analysis. Determination principle: Fluorescence DO detector is based on the principle of quenching of active fluorescence in a specific substance in physics. The blue light emitted by a light-emitting diode (LED) shines on the fluorescent substance on the inner surface of the fluorescent cap. The fluorescent substance on the inner surface receives the excitation and emits red light. By detecting the phase difference between the red light and the blue light and calibrating with the internal calibration Value comparison, which calculates the concentration of oxygen molecules, after the temperature and pressure automatically output the final output value.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com