Brief introduction First the compressor suction clean air, compressed guide to cooling pipe, compressed air by the cooling fan and the decrease of temperature, supersaturation. Wet air from the cooling pipe out through a water filter, filtering water through the electromagnetic drain valve from the panel after discharge. Not completely dry air through a safety valve, and then enter the molecular sieve regeneration scrubber, remove the remaining water vapor.Dry air through a one-way valve into the cylinder. Cylinders are used to store gases, and air Automatic switch. The gas out of the cylinder by a pressure reducing valve control pressure output for (0.20 0.02 MPa), the pressure value is displayed on the front panel of the pressure gauge. After decompression of dry air into the scrubber, first of all in no converter will be no oxidation to NO2 and in activity of carbon scrubber will NO2, O3, SO2, CO2 and other gases absorbed. Finally, the clean and dry air is passed through an end filter, which is output from the rear panel of the panel Features Can filter SO2,NO,NO2,O3,CO Condensate filter for primary filtration of wet air, condensation water automatic discharge. The regeneration of the air scrubber is completely dry, clean and high efficiency, no maintenance. Zero air through the air pressure regulator control to ensure the stability of the output pressure. Built in safety valve for overpressure protection. The air pressure switch automatically controls the start and stop of the compressor. The whole instrument is automatically controlled by CPU. Built in double cylinder compressor. With incoming call automatic start function. Technical parameter Zero Gas purity: SO2≤0.1ppb, H2S≤≤0.1ppb, NO2≤0.1ppb, NO≤0.1ppb, NH3≤0.1ppb, O3≤0.4ppb, CO≤0.02ppm, HC≤0.5ppb Output Pressure Range: 0.06~0.42MPa Output Flow: >10L/min (0.20±0.02Mpa) Others: High temperature furnace and optional HC hydrocarbon eliminating device. Dew Point: <-20℃ Power: 220VAC±10%, 50Hz
Brief introduction First the compressor suction clean air, compressed guide to cooling pipe, compressed air by the cooling fan and the decrease of temperature, supersaturation. Wet air from the cooling pipe out through a water filter, filtering water through the electromagnetic drain valve from the panel after discharge. Not completely dry air through a safety valve, and then enter the molecular sieve regeneration scrubber, remove the remaining water vapor.Dry air through a one-way valve into the cylinder. Cylinders are used to store gases, and air Automatic switch. The gas out of the cylinder by a pressure reducing valve control pressure output for (0.20 0.02 MPa), the pressure value is displayed on the front panel of the pressure gauge. After decompression of dry air into the scrubber, first of all in no converter will be no oxidation to NO2 and in activity of carbon scrubber will NO2, O3, SO2, CO2 and other gases absorbed. Finally, the clean and dry air is passed through an end filter, which is output from the rear panel of the panel