Brief introduction: Microbial turbidimetry WBS - 100 meter, 2005 edition of "pharmacopoeia of the People's Republic of China" regulation on the basis of reference USP28, BP2004, EP5.0, JP14 requirements, combined with rich practical experience and development of a new generation of microorganism titer measurement instrument, with advanced CPU 4 multivariate control management mode, the original online real-time scanning detection patent technology, antibiotics can be one, two, three doses were determined. Features: 1, set temperature and vibration wave, cultivate and on-line detection and other functions into one, fully automatic operation; Each culture can be placed in the two sets of Latin square, a total of 40 a test tube, it can be finished in 3 ~ 4 hours at the same time two or two groups of determination of antibiotic titer. 2, intelligent terminal, judgment, guarantee the accuracy of determination results. 3, real-time monitoring of bacterial growth, bacterial growth curve drawing automatically. 4, titer results conform to the 2005 edition of pharmacopoeia of the People's Republic of China "one, two, three doses of law rules. 5, can be output in line with the GLP/GMP experiment report, also will be the result of the experiment according to the specified format printing. 6, safe and reliable instrument login and password protection, in line with the requirements of GLP/GMP about electronic signature. 7, according to the Latin square tube, follow the international general method, effectively reduce the system error influence titer results. 8, using adaptive pid temperature control, improve the temperature control precision. 9, built-in ultraviolet light sterilization, effectively kill residual bacteria. Technical parameters: Temperature control precision: plus or minus 0.1 ℃ Temperature uniformity: plus or minus 0.3 ℃ The heating speed: 1.5 ℃ / min Temperature control: room temperature ~ 60 ℃ Testing cycle: 25 seconds / 40 Titer computation time: < 0.1 seconds Accuracy: 0.001 A Repeatability: + / - 0.001 A Titer repeated measurement accuracy: 0.5% or less
Microbial turbidimetry WBS - 100 meter, 2005 edition of "pharmacopoeia of the People's Republic of China" regulation on the basis of reference USP28, BP2004, EP5.0, JP14 requirements, combined with rich practical experience and development of a new generation of microorganism titer measurement instrument, with advanced CPU 4 multivariate control management mode, the original online real-time scanning detection patent technology, antibiotics can be one, two, three doses were determined.