Analysis system: Test speed: constant speed 200 T/h(without ISE) Test principle: absorption spectrometry, transmission turbidimetric method Test methods: end point method, fixed time method (two-point method), dynamic method (rate method) Test sequence: determine in strict sample order and insert at any time Online samples: 27 per batch, unlimited input multiple batches Zui long reaction time: 15 minutes Zui small reaction volume: 150 Colorimetric cup material: transparent ultraviolet plastic Channel number: 81 Colorimetric cup usage: one-time use, manual replacement Optical system: Light source: halogen tungsten lamp, 12V 20W, life more than 2000 hours Light distribution: after light distribution Wave length: 340~800nm, optional wavelength Detector: photoelectric secondary tube array Linear range of absorbance: 0 ~ 4Abs Stray light: not greater than 0.3% Resolution: 0.0001Abs Sampling and stirring system: The sample size: 2 ~ 30 can be increased by 0.1 Sample disc: disk type, 27 sample bits Sample needle: Shared with reagent needle, highly polished internal and external wall, with liquid level detection, tracking with quantity and anti-collision function (red light: collision; Blue light on: the liquid surface is detected). The sample needle is equipped with special cleaning solution to prevent contamination The amount of the test: 20 ~ 300 will be the same as the l, and 1 will be increased Test plate: arc plate type, 30 reagent levels Testing needle: it is Shared with the sample needle, and the inner and outer walls are highly polished. It has the functions of liquid level detection, pre-heating, tracking with quantity and preventing collision (red light: collision). Blue light on: liquid level detected) Test bottle: reagent bottle with volume of 15ml and 30ml can be used. The dead volume is less than 0.5ml Mixing rod: unique mixing system, good mixing effect Temperature control system: Heating method: fixed constant temperature and fully closed direct heat Temperature equilibrium time of reaction liquid: less than 3 minutes Refrigerated reagent storehouse function (optional) : 4 ~ 12 ℃ Reaction temperature: 37 plus or minus 0.2 ℃ Temperature fluctuation: plus or minus 0.1 ℃ Operating software: Operating system: Windows 2000 server, Windows xp Database: SQL server Data storage: automatic storage, automatic backup, no time and storage restrictions, permanent storage of all kinds of data Print content: you can customize the print content as you wish Print format: you can customize any print format to provide several common formats Calibration types: linear, log-4p, log-5p, spline, factor, polynomial; Automatically check the calibration curve, and automatically select the calibration type with good fit zui Type of quality control: real-time quality control, quality control within the day, quality control between the day Quality control diagram: l-j, Cumulative, Twin Plot Quality control rules: any custom, the default is Westguard Status monitoring: real-time monitoring of sample plate, reagent plate, reaction plate and quality control status; Monitoring of reaction cup, bulb and pure water: real-time display of reaction plate temperature, reagent residue, reaction curve, calibration curve and quality control diagram Verification judgment: judgment of reaction end point, judgment of reaction linear interval, judgment of bottom material consumption, detection of front band, judgment of reagent blank absorbance Other: Water consumption: less than 1 litre per hour Power source: AC 220V plus or minus 22V, 50Hz plus or minus 1Hz Work rate: zui is 200VA Dimensions: length * width * height: 930 * 760 * 1300mm Net weight: 86 kg Standard configuration: analysis department, operating software