Application Mode Portable Design |
Application Mode Portable Design |
Qualitative mode Infrared spectra |
Qualitative mode Infrared spectra |
Instrument detection limit 0.4mg/L petroleum standard solution |
Instrument detection limit 0.4mg/L petroleum standard solution |
The maximum range of the instrument 800mg/L petroleum standard solution |
The maximum range of the instrument 800mg/L petroleum standard solution |
Method detection limit 0.01mg/L oil |
Method detection limit 0.01mg/L oil |
Sample measurement range 0 to 100% oil (enriched or diluted) |
Sample measurement range 0 to 100% oil (enriched or diluted) |
The measured value is based on ρ=X•A2930+Y•A2960+Z•(A3030-A2930÷F) |
The measured value is based on ρ=X•A2930+Y•A2960+Z•(A3030-A2930÷F) |
Accuracy 100mg/L±10% |
Accuracy 100mg/L±10% |
Accuracy of CH2 20mg/L±10% |
Accuracy of CH2 20mg/L±10% |
Accuracy of CH3 20mg/L ±10% |
Accuracy of CH3 20mg/L ±10% |
100mg/L Reference Material Accuracy ±8% |
100mg/L Reference Material Accuracy ±8% |
50mg/L Reference Material Accuracy ±10% |
50mg/L Reference Material Accuracy ±10% |
5mg/L reference material accuracy ±10% |
5mg/L reference material accuracy ±10% |
Reproducibility < 1% (measured 11 times with 100 mg/L petroleum standard solution) |
Reproducibility < 1% (measured 11 times with 100 mg/L petroleum standard solution) |
Absorbance range 0.00000 to 2.00000 (A) Logarithmic scale |
Absorbance range 0.00000 to 2.00000 (A) Logarithmic scale |
Absorbance minimum scale 0.008(A) |
Absorbance minimum scale 0.008(A) |
Measurement wavelength range 3200nm to 3550nm |
Measurement wavelength range 3200nm to 3550nm |
Wavelength resolution 2.5nm |
Wavelength resolution 2.5nm |
Wavelength repeatability ±1nm |
Wavelength repeatability ±1nm |
Scanning wave number range 3400cm-1 to 2400cm-1 |
Scanning wave number range 3400cm-1 to 2400cm-1 |
Wavenumber accuracy ±1cm-1 |
Wavenumber accuracy ±1cm-1 |
Extraction solvents Carbon tetrachloride and tetrachloroethylene |
Extraction solvents Carbon tetrachloride and tetrachloroethylene |
Correlation coefficient r ≥ 0.999 |
Correlation coefficient r ≥ 0.999 |
Characteristic map scanning speed < 1 minute/time |
Characteristic map scanning speed < 1 minute/time |
Zero stability without drift |
Zero stability without drift |
Quartz cuvette specifications 0.5cm to 5cm |
Quartz cuvette specifications 0.5cm to 5cm |
Workstation connection method Built-in computer (no external workstation required) |
Workstation connection method Built-in computer (no external workstation required) |
Workstation System Windows 7 |
Workstation System Windows 7 |
The best use temperature 20 °C ~ 25 °C |
The best use temperature 20 °C ~ 25 °C |
Optimal humidity < 50%RH |
Optimal humidity < 50%RH |
Weight 15.6kg |
Weight 15.6kg |
500mm × 400mm × 220mm |
500mm × 400mm × 220mm |
Power supply 220V, 40W (AC) |
Power supply 220V, 40W (AC) |