1
Number of transmitting and receiving channels and working mode |
A total of 11 channels, 9 channels of cyclic operation, each channel is transmitted and received,And set up 2 special application channels |
Channel frequency range | 2~4MHz |
Dynamic Range | When the suppression is minimum, it is not less than 16dB, and when the suppression is maximum, it is 2~6dB. |
repeat frequency | 400Hz per channel |
Waveform display mode | A variety of display options are available, including A-type display, B-type display, A/B display, etc. |
examination range | With automatic and 43, 50, 60, 75kg / m each file; controlled by software, automatically set |
Horizontal linearity error | ≤1% |
Vertical linearity | ≤15% |
Alarm mode | Including real-time alarm, optional screw-hole double-wave alarm and lost-wave alarm, over-speed alarm, probe coupling failure alarm, etc. |
Alarm indication | Using sound and light combined with alarm mode, simultaneously displaying the sound path, horizontal and vertical distance of the alarm defect wave |
Adjustable gain curve | The user can adjust the gain curve according to actual needs to meet the requirements of actual flaw detection. |
Dynamic flaw detection capability |
With 0°, 37°, 70° rail-specific probes, you can find rail comparison test blocks.All manual defects and corresponding alarm indications |
Continuous working time | ≥8h |
weight | 27Kg (including trolley, instrument host, battery pack, charger) |
Water tank capacity | ≥17L |
Number of transmitting and receiving channels and working mode |
A total of 11 channels, 9 channels of cyclic operation, each channel is transmitted and received,And set up 2 special application channels |
Imaging display area | 1500×300 |
Imaging color | customize |
Display accuracy | 2 mm on the ordinate and abscissa |
Real-time refresh rate | 50 Hz |
Image representation range | 1500 mm |
Encoding wheel resolution | 2 mm |
Walking distance error | ≤1% |
Maximum speed of flaw detection |
5.0 km/h |
Number of image synthesis channels |
9 channels |