1 Sales GC-9760A Transformer Oil Portable Portable Chromatograph,Manufacturer
Position: Home > > Industrial on-line and process control > Industrial chromatograph > On-line gas chromatography > GC-9760A Transformer Oil Portable Portable Chromatograph for Transformer site analysis

GC-9760A Transformer Oil Portable Portable Chromatograph for Transformer site analysis

Product ID:GYSP003

Price: Please inquire PDF Format
Supply Ability:20 SETS/MONTH
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGC-9760A
    Brand NameSHHA
    Payment TermsT/T,paypal
    Introduction:
    In order to meet the needs of power system analysts who need to carry instruments to the fault site away from the laboratory for transformer oil analysis, our company has designed a GC-9760A transformer oil special portable chromatograph, which integrates all components such as computer and gas source. Together, the number of parts of the entire system is compressed to 2 pieces, which makes it truly portable. The instrument adopts the classic three-detector process to complete the analysis of the contents of seven gas components such as H2, CO, CO2, CH4, C2H4, C2H6 and C2H2 dissolved in the insulating oil in one injection. If necessary, The content of O2 and N2 can be detected. Executive Standard: GB/T 17623-1998 "Gas Chromatographic Determination of Dissolved Gas Components in Insulating Oils" GB/T 7252-2001 "Guidelines for Analysis and Judgment of Dissolved Gases in Transformer Oils" DL/T 703-1999 "Insulation Gas chromatographic determination of gas content in oil
    Technical Parameters:
    Detection range and detection limit (in μL/L):
    Component: Detection range
    H2: 2-10000
    CO: 2-50000
    CO2: 2-50000
    CH4: 0.1-2000
    C2H4: 0.1-2000
    C2H6: 0.1-2000
    C2H2: 0.1-2000
    Detector specifications:
    Thermal Conductivity Detector (TCD): Hydrogen Flame Ionization Detector (FID)
    Semi-diffused structure: cylindrical collector structure design, quartz nozzle, extremely high response
    The power supply adopts constant current control mode: automatic ignition; stabilization time: ten minutes
    Sensitivity: ≥2500mV•ml/mg (n-hexadecane/isooctane) Detection limit: ≤8×10-12g/s (n-hexadecane/isooctane)
    Baseline noise: ≤20μV Baseline noise: ≤2×10-13A
    Baseline drift: ≤100μV/30min Baseline drift: ≤2×10-12A/30min
    Linearity: ≥104 Linear: ≥106
    Temperature control indicators:
    Oven: 8 ° C ~ 400 ° C ± 0.1 ° C at room temperature
    Hydrogen Flame (FID) Detector: 8 ° C ~ 400 ° C ± 0.1 ° C at room temperature
    Thermal Conductivity (TCD) Detector: 8 ° C ~ 400 ° C ± 0.1 ° C at room temperature
    Ni catalyst converter: 8 ° C ~ 400 ° C ± 0.1 ° C at room temperature
    Dimensions: 380*450*180mm
    Weight: <15kg
    Power supply: AC220V±10 50Hz

  • Introduction:
    In order to meet the needs of power system analysts who need to carry instruments to the fault site away from the laboratory for transformer oil analysis, our company has designed a GC-9760A transformer oil special portable chromatograph, which integrates all components such as computer and gas source. Together, the number of parts of the entire system is compressed to 2 pieces, which makes it truly portable. The instrument adopts the classic three-detector process to complete the analysis of the contents of seven gas components such as H2, CO, CO2, CH4, C2H4, C2H6 and C2H2 dissolved in the insulating oil in one injection. If necessary, The content of O2 and N2 can be detected. Executive Standard: GB/T 17623-1998 "Gas Chromatographic Determination of Dissolved Gas Components in Insulating Oils" GB/T 7252-2001 "Guidelines for Analysis and Judgment of Dissolved Gases in Transformer Oils" DL/T 703-1999 "Insulation Gas chromatographic determination of gas content in oil
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com