1 Sales DZ-STA401 lifting synchronous thermal analyzer,Manufacturer
Position: Home > > Physical property test > Thermal analysis instrument > Synchronous thermal analyzer > DZ-STA401 lifting synchronous thermal analyzer

DZ-STA401 lifting synchronous thermal analyzer

Product ID:WLtb012

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberDZ-STA401
    Brand NameNJDAZHAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    DZ-STA401 lifting synchronous thermal analyzer
    Introduction:
    DZ-STA401 is anewly launched synchronous thermal analyzer by our company that can simultaneously measure TG/DSC. The instrument adopts an automatic lifting furnace structure design, making it more convenient to test samples. It is also equipped with a digital flowmeter that can automatically control the size of the gas. The software has been upgraded for more accurate analysis. The instrument can be connected to infrared for more powerful functionality.
    The DZ-STA401 synchronous thermal analyzer can simultaneously detect both TG and DSC information, with a wide range of measurements including thermal stability, oxidation-reduction, decomposition behavior, corrosiveness research, decomposition kinetics analysis, melting/crystallization, solid-phase transformation, crystallinity, glass transition, etc. The DZ-STA401 synchronous thermal analyzer is based on the temperature changes of the sample and the processes of heat conduction, absorption, and emission. It controls the temperature of the heating furnace to perform heating, cooling, and constant temperature operations on the sample, and then detects and records the temperature changes and corresponding physical and chemical properties of the sample.
    characteristic:
    1.The furnace body heating adopts a double row winding of precious metal platinum rhodium alloy wire, reducing interference and making it more resistant to high temperatures.
    2.The tray sensor is made of precious metal alloy wire and is finely crafted, with advantages such as high temperature resistance, oxidation resistance, and corrosion resistance.
    3.Separate the power supply, circulating heat dissipation part from the main unit to reduce the impact of heat and vibration on the microcalorimeter.
    4.The host adopts an isolated heating furnace to mitigate the thermal impact on the chassis and micro thermal balance.
    5.The furnace body adopts double insulation for better linearity; The furnace body is equipped with automatic lifting, which can quickly cool down; Equipped with exhaust outlet, it can be used in conjunction with infrared and other technologies.
    Technical parameters:
    temperature range Room temperature~1250 ℃
    temperature resolution 0.001℃
    Temperature fluctuations ±0.01℃
    Heating/cooling rate 0.1~100℃/min- 0.1~-40℃/min
    Temperature control method PID temperature control, heating, constant temperature and cooling
    Measurement range of weighing system 0.01mg~3g, expandable to 50g
    accuracy 0.01mg
    resolution 0.01ug
    DSC range ±1000mW
    DSC sensitivity 0.0001mW
    atmosphere control Built in digital flowmeter, automatic control of gas size
    software Intelligent software can automatically record TG and DSC curves for data processing. The software has an automatic adjustment function and automatically extends and scales according to the graph display
    holding time Arbitrary setting, standard configuration ≤ 600min
     
     
     
  • Introduction:
    DZ-STA401 is anewly launched synchronous thermal analyzer by our company that can simultaneously measure TG/DSC. The instrument adopts an automatic lifting furnace structure design, making it more convenient to test samples. It is also equipped with a digital flowmeter that can automatically control the size of the gas. The software has been upgraded for more accurate analysis. The instrument can be connected to infrared for more powerful functionality.
    The DZ-STA401 synchronous thermal analyzer can simultaneously detect both TG and DSC information, with a wide range of measurements including thermal stability, oxidation-reduction, decomposition behavior, corrosiveness research, decomposition kinetics analysis, melting/crystallization, solid-phase transformation, crystallinity, glass transition, etc. The DZ-STA401 synchronous thermal analyzer is based on the temperature changes of the sample and the processes of heat conduction, absorption, and emission. It controls the temperature of the heating furnace to perform heating, cooling, and constant temperature operations on the sample, and then detects and records the temperature changes and corresponding physical and chemical properties of the sample.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com