Features: 1,7-inch industrial-grade widescreen touch structure, display rich information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, a variety of switch status. 2, up and down the optical adjustment bracket, it can be very convenient to adjust the irradiation light source and sample irradiation distance. 3, high temperature thermal insulation quartz glass furnace cover, both play the effect of thermal insulation, but also easy to light exposure and observation. 4, optional light control system. Precise control of light source on and sample cure time calculations. The wavelength of light, intensity of light, light at a specific temperature can be very easily observed The impact of the irradiation time on the product. Rapid determination of material stability and aging effects. 5, USB3.0 communication, fast mass transmission of data, versatility, reliable communication without interruption, support for self-recovery connection. 6, one-piece fixed furnace structure, no need to lift the furnace up and down, add convenient, adjustable heating rate can be adjusted. 7, Removable sample support rod can be replaced flexibly to meet the different needs of users, to facilitate the cleaning and maintenance of contaminated samples. 8, heating furnace heating wire, furnace cooling electronic semiconductor cooling, compact structure, small size. No external cooling source and tedious refrigeration system, heating and lowering Fast temperature, minimum cooling temperature up to -40 degrees. 9, dual temperature probe, to ensure high temperature measurement sample repeatability. All the way temperature probe installed in the furnace wall for PID control the temperature of the entire furnace, but due to the temperature of the hot habit Sex, the temperature transmitted to the sample have a certain deviation, and the spring summer autumn and winter deviations are not the same, therefore, the use of single-temperature probe temperature and temperature control, either differential heat signal or temperature signal Number, the error is relatively large; The instrument at the bottom of the sample more installed a temperature probe for measuring the true temperature of the sample, and uses our special temperature control technology, control The furnace wall temperature allows the sample temperature to reach the set temperature. 10, gas mass flow meter automatically switches two air flow, switching speed, short stabilization time. 11, standard standard samples, to facilitate customers to adjust the constant temperature coefficient. 12, the software adapts to the resolution of the computer screen, the software automatically adjusts the display of each curve according to the size of the computer screen. Support laptop, desktop, support WIN XP, WIN 7, WIN 8, WIN10 and other operating systems. 13, the user self programming, measurement steps to achieve full automation. Software provides dozens of instructions, users can flexibly combine instructions according to their own measurement steps and save. complicated Operation simplifies to one-click operation. 14, high-grade aluminum equipment box, equipped with high-pressure stretch foam packaging, customers can carry and move at will. Technical Parameters: Temperature range: -40 ℃ ~ 500 ℃ Temperature resolution: 0.01 ℃ Temperature fluctuation: ± 0.1 ℃ Heating rate: 0.1 ~ 80 ℃ / min optional Temperature control method: PID temperature adjustment DSC range: 0 ~ ± 500mW DSC Resolution: 0.001 μW DSC sensitivity: 0.001 μW Atmosphere control: nitrogen, oxygen two gas control Working power: AC 220V 50Hz
Features: 1,7-inch industrial-grade widescreen touch structure, display rich information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, a variety of switch status. 2, up and down the optical adjustment bracket, it can be very convenient to adjust the irradiation light source and sample irradiation distance. 3, high temperature thermal insulation quartz glass furnace cover, both play the effect of thermal insulation, but also easy to light exposure and observation. 4, optional light control system. Precise control of light source on and sample cure time calculations. The wavelength of light, intensity of light, light at a specific temperature can be very easily observed The impact of the irradiation time on the product. Rapid determination of material stability and aging effects. 5, USB3.0 communication, fast mass transmission of data, versatility, reliable communication without interruption, support for self-recovery connection. 6, one-piece fixed furnace structure, no need to lift the furnace up and down, add convenient, adjustable heating rate can be adjusted. 7, Removable sample support rod can be replaced flexibly to meet the different needs of users, to facilitate the cleaning and maintenance of contaminated samples. 8, heating furnace heating wire, furnace cooling electronic semiconductor cooling, compact structure, small size. No external cooling source and tedious refrigeration system, heating and lowering Fast temperature, minimum cooling temperature up to -40 degrees. 9, dual temperature probe, to ensure high temperature measurement sample repeatability. All the way temperature probe installed in the furnace wall for PID control the temperature of the entire furnace, but due to the temperature of the hot habit Sex, the temperature transmitted to the sample have a certain deviation, and the spring summer autumn and winter deviations are not the same, therefore, the use of single-temperature probe temperature and temperature control, either differential heat signal or temperature signal Number, the error is relatively large; The instrument at the bottom of the sample more installed a temperature probe for measuring the true temperature of the sample, and uses our special temperature control technology, control The furnace wall temperature allows the sample temperature to reach the set temperature. 10, gas mass flow meter automatically switches two air flow, switching speed, short stabilization time. 11, standard standard samples, to facilitate customers to adjust the constant temperature coefficient. 12, the software adapts to the resolution of the computer screen, the software automatically adjusts the display of each curve according to the size of the computer screen. Support laptop, desktop, support WIN XP, WIN 7, WIN 8, WIN10 and other operating systems. 13, the user self programming, measurement steps to achieve full automation. Software provides dozens of instructions, users can flexibly combine instructions according to their own measurement steps and save. complicated Operation simplifies to one-click operation. 14, high-grade aluminum equipment box, equipped with high-pressure stretch foam packaging, customers can carry and move at will.