D18-I infrared spectrophotometer for oil measurement

Product ID:HSYJcy047

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberD18-I
    Brand NameHONGYUANKEYI
    Payment TermsTT,PAYPAL
    D18-I infrared spectrophotometer for oil measurement
    Introduction:
    The D18-I infrared spectrophotometer is mainly used for measuring the oil content in industrial wastewater, as well as for monitoring the oil content in the smoke and solid of the catering industry. This instrument is a professional instrument for measuring oil content in water bodies, gases, and solids.
    Features:
    1. Structural design: Aluminum alloy is lightweight and has good heat dissipation performance;
    2. Modulation light source: Use a low-voltage power source to reduce temperature interference and ensure instrument stability;
    3. Imported light source: equipped with imported light source, low power, low voltage, greatly improving the lifespan of the light source, maintenance free;
    4. Light source drive: High frequency chopping mode, eliminating benzene interference and improving performance to noise ratio;
    5. Optical design: Adopting a polarizing elliptical condenser design, the light source can be observed focusing on the receiving area of the detector, which is convenient for maintenance;
    6. Strictly implement the HJ637-2018 national standard, without the need for standard curve data correction, only one set of correction coefficients (X, Y, Z, F) should be applied
    Technical parameters:
    Qualitative method: infrared spectrum scanning
    Wavenumber position accuracy: Polypropylene film wavenumber positioning, instrument wavenumber resolution of 0.5nm
    Measurement basis: ρ=X • A2930+Y • A2960+Z • (A3030-A2930 ÷ F)
    CH accuracy: 100mg/L ± 5% (standard 8.1.1 requires not to use standard curves to measure benzene)
    CH2 accuracy: 20mg/L ± 5% (standard 8.1.1 requires no use of standard curve to measure n-hexadecane)
    CH3 accuracy: 20mg/L ± 5% (standard 8.1.1 requires no use of standard curve for measuring isooctane)
    Extraction solvents: carbon tetrachloride, tetrachloroethylene, trichlorotrifluoroethane, S316
    Zero point stability: eliminating errors caused by drift through real-time measurement of blanks

     
     
  • Introduction:
    The D18-I infrared spectrophotometer is mainly used for measuring the oil content in industrial wastewater, as well as for monitoring the oil content in the smoke and solid of the catering industry. This instrument is a professional instrument for measuring oil content in water bodies, gases, and solids.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com