ATP5104 UV Enhanced High Performance Fiber Spectrometer Introduction
ATP5104 is a high-performance UV-enhanced micro-fiber spectrometer specially developed for the ultraviolet spectrum. It uses a 3072-pixel UV-sensitized linear CCD to adapt to the 165-1100nm wavelength range. The CCD detector exposure time can be controlled. Within 1ms, at the same time, the Austrian Spectrum became the ATP5104 specially customized ultra-low noise CCD signal processing circuit, its quantization noise is less than 3 counts, which is the best level in the industry and can help you get a very high spectral signal-to-noise ratio.
The ATP5104 is ideal for UV, visible, and near-infrared spectroscopy applications. Different slits, gratings, mirrors, and filters are available. Depending on your needs, the spectrometer can be configured for different applications. The spectral range is from 165nm. Up to 1050nm, the spectral resolution can be chosen from 0.5 to 4.0nm, and the company can also provide OEM customers with customized options.
The ATP5104 can receive the SMA905 interface fiber input or free space input of the light to be measured, measure according to the set integration time, and output the measurement result through USB2.0 (high speed) or UART output;
Feature
1.UV enhanced high performance back-illuminated CCD
2.Optical paths and structures optimized for UV;
3.Detector: back-illuminated CCD
4.Detector pixels: 3072
5.Ultra low noise CCD signal processing circuit
6.Spectral range: 165-1100 nm
7.Spectral resolution: 0.1-4 nm (depending on spectral range, slit width)
8.Optical path structure: cross C-T
9.Integration time: 2ms-130s
10.Power supply: DC 5V ± 10% @ <2.3A
11.18 bit, 570KHz A/DConverter
12.Optical input interface: SMA905 or free space
13.Data output interface: USB2.0 (High speed) or UART
14.20-pin dual-row programmable expansion interface
Technical Parameters DETECTOR
Type: Line array back-illuminated CCD
Detection spectral range: 165-1100 nm
Effective pixels: 3072
Cell size: 600μm × 8μm
Full scale range: ~200 ke-
Sensitivity: 6.5 uV/e-
Dark noise: 6 e- OPTICAL PARAMETER
Wavelength range: 165-1100 nm
Optical resolution: 0.1-4 nm (depending on slit, spectral range)
SQ ratio: >1000:1
Dynamic range: 3000:1
Working temperature: -10-40 oC
Working humidity: < 85%RH OPTICAL CONFIGURATION
Optical design: f/4 cross-symmetric C-T optical path
Focal length: 40 mm for incidence / 60 mm for output
Incident slit width: 5, 10, 25, 50, 100, 150, 200 μm optional, other sizes can be customized
Incident optical interface: SMA905 fiber interface, free space ELECTRICAL PARAMETER
Integration time: 1 ms - 130 second
Data output interface: USB 2.0
ADC bit depth: 18 bit
Power supply: DC 5V ± 10%
Working current: <2.3A
Storage temperature: -20°C to +70°C
Operating temperature: -10°C to +40°C PHYSICAL PARAMETERS
Size: 102 × 720 × 34 mm3
Weight: 0.3 kg
Sealing: Anti-sweat
Introduction
ATP5104 is a high-performance UV-enhanced micro-fiber spectrometer specially developed for the ultraviolet spectrum. It uses a 3072-pixel UV-sensitized linear CCD to adapt to the 165-1100nm wavelength range. The CCD detector exposure time can be controlled. Within 1ms, at the same time, the Austrian Spectrum became the ATP5104 specially customized ultra-low noise CCD signal processing circuit, its quantization noise is less than 3 counts, which is the best level in the industry and can help you get a very high spectral signal-to-noise ratio.
The ATP5104 is ideal for UV, visible, and near-infrared spectroscopy applications. Different slits, gratings, mirrors, and filters are available. Depending on your needs, the spectrometer can be configured for different applications. The spectral range is from 165nm. Up to 1050nm, the spectral resolution can be chosen from 0.5 to 4.0nm, and the company can also provide OEM customers with customized options.