Introduction: Building material smoke density tester is used to measure the static smoke density of building materials under the test conditions of combustion or decomposition. The smoke density test is carried out by testing the loss of luminous flux in the test chamber, and flame and smoke can be observed during the test. phenomenon. Compliance with standards: ASTM D2843 GB/T 8627; Area of application: Determination of static smoke production from burning of building materials and their products and other materials. It is mainly used for the evaluation of flame retardant grade B1 of insulation materials such as extruded board and polystyrene board. Features: 1. Accurate and fast data acquisition function 2. Transparent tempered glass door for easy observation and testing; 3. Stainless steel sample holder and sample template; 4. Precision needle type regulating valve regulates gas flow 5. Software control, user-friendly design, to avoid the impact of human factors on the test. 6. Stable optical path system 7. Using imported linear silicon photocells, dedicated silicon photocell signal amplifiers. 8. Guarantee excellent linear electrical signal output of the optical path system 9.NI data acquisition card, with desktop computer software control: 10. Automatic ignition and ignition abnormal protection; Technical Parameters: 1. Model: 5910 2. Measurement range: 0-100% 3. Measurement accuracy: less than the reading value x3% 4. Resolution: 0.1% 5. Flame height: 20-70mm adjustable 6. Gas pressure: adjustable from 80-350KP 7. Test time: 0-999S 8. Light source voltage: 5.8V DC lens focal length: 60-65mm 9. Material: cold plate powder paint (black) 10. There is a vent at the bottom: 25x230mm 11. Exhaust device: 1700L/min 12. Burner: all copper nozzle diameter: 0.13mm 13. Box size: width 300 × depth 300 × height 790mm 14. Outer dimensions: width 550 × depth 500 × height 850 15. Power: 220VAC 10A 50HZ 16. Weight: 35kg
Introduction: Building material smoke density tester is used to measure the static smoke density of building materials under the test conditions of combustion or decomposition. The smoke density test is carried out by testing the loss of luminous flux in the test chamber, and flame and smoke can be observed during the test. phenomenon. Compliance with standards: ASTM D2843 GB/T 8627; Area of application: Determination of static smoke production from burning of building materials and their products and other materials. It is mainly used for the evaluation of flame retardant grade B1 of insulation materials such as extruded board and polystyrene board.