Product introduction: The zw-tw-hlv2500w asepsis isolation system integrates the operation chamber, transfer window and vaporized hydrogen peroxide generator (VHP). Integration of the vaporization of hydrogen peroxide sterilization (VHP) to kill bacteria in the cabin, lab (operating room) positive pressure maintaining in aseptic condition, lab for the first time after sterilization, transfer module (sanitizers tank) can be independent of the rapidly into the lab inspection product surface sterilization, goods by the transfer between the two compartment door into the lab, realizing a continuous inspection goods. The sterilization process of vaporized hydrogen peroxide used in aseptic test isolator has a short time of sterilization, and the sterilization period of the transfer chamber is about 1 hour, which greatly improves the working efficiency. Complete sterilization, can reduce thermophilic adipose bacillus (ATCC12980 or ATCC7953) by 6-log; Good repeatability, patented drug delivery method and unique control method, good reproducibility and verifiable sterilization; Environmentally friendly, hydrogen peroxide decomposed into water and oxygen, non-toxic and non-residue advantages; The risk of false positive can be effectively avoided by using aseptic testing isolator for aseptic testing. Technical parameters: 1. Power supply: AC220V plus or minus 22V / 50Hz 2. Power: 3000VA 3. External dimension: customization 4. Noise: no more than 65dB (A) (sterile maintenance) 5. Working pressure: -80 ~ 80Pa (adjustable) 6. Cleanliness: class A 7. Airflow model: turbulence (turbulence) of operating cabin and laminar flow of transfer window 8. Killing rate: thermophilic adipose bacillus decreased by 6-log 9. Hydrogen peroxide: 30% (analytical purity) 10. Sterilization cycle: about 60min for the transfer cabin, and about 160min for the test cabin + transfer cabin 11. Operation port: 6 or 8 (double-sided operation) 12. Differential pressure resolution: 0.1pa 13, temperature resolution: 0.1 ℃ 14. Humidity resolution: 0.1%RH 15. Hourly leakage rate: Q/V is less than or equal to 0.5% 16. High efficiency filter: H14 (confield)
Product introduction: The zw-tw-hlv2500w asepsis isolation system integrates the operation chamber, transfer window and vaporized hydrogen peroxide generator (VHP). Integration of the vaporization of hydrogen peroxide sterilization (VHP) to kill bacteria in the cabin, lab (operating room) positive pressure maintaining in aseptic condition, lab for the first time after sterilization, transfer module (sanitizers tank) can be independent of the rapidly into the lab inspection product surface sterilization, goods by the transfer between the two compartment door into the lab, realizing a continuous inspection goods. The sterilization process of vaporized hydrogen peroxide used in aseptic test isolator has a short time of sterilization, and the sterilization period of the transfer chamber is about 1 hour, which greatly improves the working efficiency. Complete sterilization, can reduce thermophilic adipose bacillus (ATCC12980 or ATCC7953) by 6-log; Good repeatability, patented drug delivery method and unique control method, good reproducibility and verifiable sterilization; Environmentally friendly, hydrogen peroxide decomposed into water and oxygen, non-toxic and non-residue advantages; The risk of false positive can be effectively avoided by using aseptic testing isolator for aseptic testing.