ZR-3713 Dual VOCs Sampler Introduction
ZR-3713 dual-channel VOCs sampler adopts adsorption tube sampling method and other solid-phase adsorption methods, which can collect volatile organic compounds such as benzene series, aldehydes and ketones, halogenated hydrocarbons in ambient air, and simultaneously with flue gas. The processor can also be used to determine the volatile organic compounds in the fixed source exhaust gas.
Executive standard
HJ 644-2013 Ambient Air Determination of Volatile Organic Compounds Sampling Tube Sampling-Thermal Desorption/Gas Chromatography-Mass Spectrometry
HJ645-2013 Ambient air Determination of volatile halogenated hydrocarbons Activated carbon adsorption-carbon disulfide desorption/gas chromatography
HJ 683-2014 Ambient air Determination of aldehydes and ketones - High performance liquid chromatography
HJ583-2010 Ambient air Determination of benzene series Solid adsorption / thermal desorption - Gas chromatography
HJ584-2010 Ambient air Determination of benzene series Activated carbon adsorption / Carbon disulfide desorption - Gas chromatography
HJ739-2015 Ambient air Determination of nitrobenzene compounds Gas chromatography-mass spectrometry
HJ 734-2014 Fixed source pollution - Determination of volatile organic compounds - Solid phase adsorption - Thermal desorption / Gas chromatography - mass spectrometry
HJ 38-2017 Determination of non-methane total hydrocarbons from fixed source s
GB/T16157-1996 Determination of particulate matter in fixed pollution source exhaust gas and sampling method of gaseous pollutants
HJ/T47-1999 flue gas sampler technical conditions Features
Super negative pressure: load capacity can exceed 30Kpa, easily handle high-resistance enrichment carrier sampling (benzene, TVOC, etc.), using imported brushless diaphragm pump;
Digital constant current: built-in high-precision electronic flowmeter, accurate closed-loop control, original flow control algorithm to ensure accurate control of small flow;
Multiple protection: The air filter has good protection design, and the built-in dry anti-back suction tube provides multiple protections to avoid damage to the instrument caused by particles and moisture;
Long battery life: built-in rechargeable high-performance lithium battery, fully charged continuous working time is more than 12 hours;
Free sampling mode: A/B parallel sampling, sequence sampling;
The instrument is compatible with: a variety of specifications, different filling materials and length of the adsorption tube;
Multi-purpose machine: It has sampling function such as activated carbon tube and solution absorption;
Ergonomics: With a 5.0-inch touch screen display, the content is more intuitive and easier to operate;
The connecting pipe is made of PTFE to prevent the material from volatilizing or adsorbing organic matter;
Automatically measure ambient temperature, atmospheric pressure, pre-flowmeter pressure, pre-meter temperature, and calculate the standard volume;
Portable, small and lightweight. Power-down protection function, the system automatically remembers the power-down time, and then calls to continue sampling after power failure;
With system airtight automatic leak detection function;
Support USB data export;
Optional Bluetooth printer and flue condition measurement module;
Optional GPS positioning module to record sampling position information;
Optional 4G module for remote data transmission. Technical parameters
Instrument type: smoke sampler
Flue gas flow rate: (10 ~ 200) mL / min
Sampling flow: (10 ~ 200) mL / min
Moisture content: (0 ~ 85)%
Flow accuracy: ±2.5%
Sample collection: VOCs
Introduction
ZR-3713 dual-channel VOCs sampler adopts adsorption tube sampling method and other solid-phase adsorption methods, which can collect volatile organic compounds such as benzene series, aldehydes and ketones, halogenated hydrocarbons in ambient air, and simultaneously with flue gas. The processor can also be used to determine the volatile organic compounds in the fixed source exhaust gas.
Executive standard
HJ 644-2013 Ambient Air Determination of Volatile Organic Compounds Sampling Tube Sampling-Thermal Desorption/Gas Chromatography-Mass Spectrometry
HJ645-2013 Ambient air Determination of volatile halogenated hydrocarbons Activated carbon adsorption-carbon disulfide desorption/gas chromatography
HJ 683-2014 Ambient air Determination of aldehydes and ketones - High performance liquid chromatography
HJ583-2010 Ambient air Determination of benzene series Solid adsorption / thermal desorption - Gas chromatography
HJ584-2010 Ambient air Determination of benzene series Activated carbon adsorption / Carbon disulfide desorption - Gas chromatography
HJ739-2015 Ambient air Determination of nitrobenzene compounds Gas chromatography-mass spectrometry
HJ 734-2014 Fixed source pollution - Determination of volatile organic compounds - Solid phase adsorption - Thermal desorption / Gas chromatography - mass spectrometry
HJ 38-2017 Determination of non-methane total hydrocarbons from fixed source s
GB/T16157-1996 Determination of particulate matter in fixed pollution source exhaust gas and sampling method of gaseous pollutants
HJ/T47-1999 flue gas sampler technical conditions