Introduction: Y201D is suitable for packaging materials such as high barrier film, co-extruded film, aluminum foil, aluminized film, infusion bag, sheet, coated film, solar backsheet, cellophane, ceramic flake ; Also suitable for bottles, bags, cans and other containers of oxygen permeability barrier test. Features: 1 temperature control: the use of international advanced electromagnetic temperature control technology, step-by-step procedures can easily control the temperature rise and fall, without external accessories, temperature control accuracy to the nearest 0.1 ℃. 2 Humidity Control: Adopt double air flow humidity control, large control humidity range, high precision, humidity and flow stability, to avoid the plug-in humidity lead to the device bulky, fault and more shortcomings. 3 instruments with standard gas calibration and standard membrane correction of two correction methods, the industry only through the national standard gas certification, automatic judgment, automatic shutdown. 4 a variety of automatic protection features: leaks, over-range testing, power outage data is automatically saved, misuse tips. 5 software is simple, automatic testing process. Transmission rate, oxygen concentration, humidity, temperature and other parameters automatically curve curve, continuous display. Can monitor the mutual influence between parameters, can monitor the testing process. 6 functions Modular, set, test, baseline, calibration, reporting and other functions independent of each other, a good data analysis capabilities, the operation is very convenient. 7 fast test function, suitable for product evaluation test. 8 Two test chambers independently and cross-test two different samples for efficient testing. 9 host external USB for software upgrades, data backup and troubleshooting. Technical Parameters : Test range 0.02 ~ 16500 cm3 / (m2 • 24h) (through the mask can test 260000 cm3 / (m2 • day) Temperature range of 15 ℃ ~ 45 ℃ Temperature control accuracy of ± 0.1 ℃ Dimensions 630mm × 560mm × 350mm Power AC 220V 50HZ Number of samples 2 The number of sensors 2 Sample thickness ≤ 2mm Pressure 0.1 ~ 0.2MPa Sample size Φ100mm, through the area of 50.24cm2 Test environment Room temperature (standard conditions 23 ℃) Carrier gas port 1/8 inch
Introduction: Y201D is suitable for packaging materials such as high barrier film, co-extruded film, aluminum foil, aluminized film, infusion bag, sheet, coated film, solar backsheet, cellophane, ceramic flake ; Also suitable for bottles, bags, cans and other containers of oxygen permeability barrier test.