1 Sales XDV-300A Vicat Softening Point Temperature Tester,Manufacturer
Position: Home > > Industry specific instrument > Rubber plastic industry special testing instruments > VEKA softening point tester > XDV-300A Vicat Softening Point Temperature Tester for Plastic heating performance

XDV-300A Vicat Softening Point Temperature Tester for Plastic heating performance

Product ID:HZXSwkrhd019

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberXDV-300A
    Brand NameCHENGDEJINHE
    Payment TermsT/T, paypal
    XDV-300A Vicat Softening Point Temperature Tester
     
    Introduction:
        XDV-300A Thermal Deformation•Vicat Softening Point Temperature Tester is designed with international and national standards to determine the thermal softening performance of plastic materials or finished products. By changing the pressure head, the instrument can measure the heat distortion temperature and Vicat temperature, using transformer oil (within 200°C) or methyl silicone oil (within 300°C) as the heat transfer medium, and a mechanical agitator for oil circulation in the tank, with large capacity Oil tank design, stable temperature control, uniform temperature field.
        The sample holder of this instrument adopts high-strength design to ensure that there is no slight deformation under load; it adopts low expansion coefficient materials, and the material expansion coefficients are complementary to ensure that the test result will not be affected by thermal expansion during the heating process. The thermal deformation test adopts standard spans, 64mm and 100mm respectively, and different length samples automatically adapt to different spans, which is very convenient to use. By replacing the lancet and indenter, the thermal deformation test and the Vicat test can be switched.
    Features:
        1. Support the thermal deformation test of various samples specified by the standard.
        2. Support various Vicat softening point tests specified by the standard.
        3. Optimized constant speed heating algorithm, stable and accurate heating process.
        4. Software calibration temperature.
        5. Hardware adjustment temperature error.
        6. Freely set the upper limit temperature, deformation amount and Vicat penetration depth.
        7. Use standard heating rates of 50°C/H and 120°C/H.
        8. The test will automatically stop when the upper limit temperature or deformation is reached.
        9. Touch screen man-machine interface, menu operation, simple and intuitive, easy to learn and use.
        10. Automatically record test data, save test data, browse and print test results, and export test data in the form of EXCEL table through U disk.
        11. Standard micro printer, one-key printing of test results.
    Technical parameter:
        Temperature control range: room temperature -300.
        Heating rate: 50°C/H and 120°C/H.
        Temperature measurement method: PT100 sensor, center point measurement.
        Temperature resolution: 0.1
        Temperature error: ±0.5
        Deformation measurement method: digital dial indicator or dial indicator (choose according to user requirements)
        Deformation measurement range: 0-12.7mm (can be configured according to user requirements)
        Deformation measurement error: 0.005mm (0.0005mm)
        Deformation measurement resolution: 0.01mm (0.001mm)
        Three sets of weight configuration 2000g, 1000g, 500g, 200g, 100g, 50g
        Structure: desktop
        Number of sample racks: 3 (can be customized according to user requirements)
        Thermal deformation test span: 64mm, 100mm
        Heating medium: methyl silicone oil (suitable for room temperature -300, viscosity requirement below 100CS) or transformer oil (used within 200)
        Fuel tank capacity: about 13 liters
        Heating power: 3KW
        Power supply: 220V±10% 15A 50Hz
        Cooling method: natural cooling or circulating water cooling
        Host size: 745×430×410mm
  • Introduction:
        XDV-300A Thermal Deformation•Vicat Softening Point Temperature Tester is designed with international and national standards to determine the thermal softening performance of plastic materials or finished products. By changing the pressure head, the instrument can measure the heat distortion temperature and Vicat temperature, using transformer oil (within 200°C) or methyl silicone oil (within 300°C) as the heat transfer medium, and a mechanical agitator for oil circulation in the tank, with large capacity Oil tank design, stable temperature control, uniform temperature field.
        The sample holder of this instrument adopts high-strength design to ensure that there is no slight deformation under load; it adopts low expansion coefficient materials, and the material expansion coefficients are complementary to ensure that the test result will not be affected by thermal expansion during the heating process. The thermal deformation test adopts standard spans, 64mm and 100mm respectively, and different length samples automatically adapt to different spans, which is very convenient to use. By replacing the lancet and indenter, the thermal deformation test and the Vicat test can be switched.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com