X-Porator H1 Cell electrotachometer Introduction: The X-Porator H1 Cell electrotachometer, also known as the DNA transducer, is the result of our company's four years of dedicated research and development. This device combines multiple unique patented technologies from Yida. H1 generates a uniform electric field in the cell fluid through precise control of pulse voltage, pulse waveform, pulse duration and interval time, as well as pulse repetition times, using high-density matrix needle electrodes (HiDEN technology) to directly introduce foreign substances into the target cell (electrotransfection) Features: 1. Improvement and upgrading, greatly improving quality and performance After a year, we have completed 21 electronic and structural hardware improvements, 17 software upgrades, and 41 improvements. 2. High transfection efficiency and cell viability Independently patented titanium platinum alloy electrode cup and HiDEN needle electrode technology, low voltage transfection. 3. Titanium platinum alloy electrode cup Stable and durable, not easy to produce metal ions, reducing cell toxicity. 4. Using HiDEN technology for needle electrodes The self-developed patented high-density matrix needle electrode (HiDEN) can generate a highly uniform and sufficiently strong electric field at lower voltages, achieving high transfection rates. 5. The parameters are visible and adjustable It can be used in conjunction with the Yida flow meter for parameter optimization and verification. 6. Wireless control Throughout the transfection process, the electric transfer cup and cells do not need to leave the ultraclean stage, effectively reducing the risk of sample contamination. 7. High quality after-sales service A professional experimental team provides real-time online or on-site technical support. 8. Reasonable equipment and consumables costs Technical parameters: Single well treated cell fluid volume: 60-3000 μ L Voltage waveform: square wave Pulse power supply voltage range: 1-400 V Square wave duration: 10-100000 μ S Pulse interval: 15-10000 ms Number of square waves: 1-100 Electrode: 96-, 24-, 12-well plate dedicated needle electrode/electrode cup Wireless transmission distance: 15 m Operating system platform: Android Input voltage: 210-240 VAC Boundary dimension: width 220 × Deep 408 × 180 mm high Weight: 8.2 kg
Introduction: The X-Porator H1 Cell electrotachometer, also known as the DNA transducer, is the result of our company's four years of dedicated research and development. This device combines multiple unique patented technologies from Yida. H1 generates a uniform electric field in the cell fluid through precise control of pulse voltage, pulse waveform, pulse duration and interval time, as well as pulse repetition times, using high-density matrix needle electrodes (HiDEN technology) to directly introduce foreign substances into the target cell (electrotransfection)