1 Sales WKT-YJD10 insulating oil oil dielectric loss tester,Manufacturer
Position: Home > > Industry specific instrument > Oil special analytical instrument > Other > WKT-YJD10 insulating oil oil dielectric loss tester

WKT-YJD10 insulating oil oil dielectric loss tester

Product ID:HZSYqtOther086

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberWKT-YJD10
    Brand NameTAIZHOUKETUO
    Payment TermsTT,PAYPAL
    WKT-YJD10 insulating oil oil dielectric loss tester
     
    Introduction:
    WKT-YJD10 insulating oil dielectric loss tester is a high-precision instrument used for dielectric loss angle and volume resistivity of insulating oil and other liquid insulating media. Integrated structure. The main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter, and DC high voltage source are integrated inside. The heating part adopts the high-frequency induction heating method, which has the advantages of non-contact between the oil cup and the heating body, uniform heating, fast speed, and convenient control. The AC test power supply adopts the AC-DC-AC conversion method, which effectively avoids the influence of the mains voltage and frequency fluctuations on the accuracy of the dielectric loss test. Even if the generator generates electricity, the instrument can run correctly. The internal standard capacitor is a SF6 gas-filled three-pole capacitor. The dielectric loss and capacitance of the capacitor are not affected by ambient temperature and humidity, so as to ensure that the instrument is still accurate after long-term use.
    WKT-YJD10 is mainly used for the measurement of dielectric loss factor and DC resistivity of liquid insulating medium such as insulating oil. It integrates dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, and standard capacitor. , high resistance meter, DC high voltage source and other main components. The instrument uses advanced measurement and control technology to fully automatically complete the processes of heating, temperature control, high-speed data sampling, calculation, display, printing and storage. The advanced measurement principle and highly digital technology are widely used in electric power enterprises and electric power testing departments.
    Technical parameter:
    Product model: WKT-YJD10
    Power supply voltage: AC 220V±10%
    Power frequency: 50Hz/60Hz ±1%
    Measuring range
    Capacitance: 5pF200pF
    Relative permittivity: 1.00030.000
    Dielectric loss factor: 0.00001100
    DC resistivity: 2.5 MΩm20 TΩm
    measurement accuracy
    Capacitance: ±(1% reading+0.5pF)
    Relative permittivity: ±1% of reading
    Dielectric loss factor: ±(1% reading+0.0001)
    DC Resistivity: ±10% of reading
    Resolution
    Capacitance: 0.01pF
    Relative permittivity: 0.001
    Dielectric loss factor: 0.00001
    Temperature measurement range: 0125
    Temperature measurement error: ±0.5
    AC experiment voltage: 5002200V continuously adjustable, frequency 50Hz
    DC test voltage: 0500V continuously adjustable
    Power consumption: 100W
  • Introduction:
    WKT-YJD10 insulating oil dielectric loss tester is a high-precision instrument used for dielectric loss angle and volume resistivity of insulating oil and other liquid insulating media. Integrated structure. The main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter, and DC high voltage source are integrated inside. The heating part adopts the high-frequency induction heating method, which has the advantages of non-contact between the oil cup and the heating body, uniform heating, fast speed, and convenient control. The AC test power supply adopts the AC-DC-AC conversion method, which effectively avoids the influence of the mains voltage and frequency fluctuations on the accuracy of the dielectric loss test. Even if the generator generates electricity, the instrument can run correctly. The internal standard capacitor is a SF6 gas-filled three-pole capacitor. The dielectric loss and capacitance of the capacitor are not affected by ambient temperature and humidity, so as to ensure that the instrument is still accurate after long-term use.
    WKT-YJD10 is mainly used for the measurement of dielectric loss factor and DC resistivity of liquid insulating medium such as insulating oil. It integrates dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, and standard capacitor. , high resistance meter, DC high voltage source and other main components. The instrument uses advanced measurement and control technology to fully automatically complete the processes of heating, temperature control, high-speed data sampling, calculation, display, printing and storage. The advanced measurement principle and highly digital technology are widely used in electric power enterprises and electric power testing departments.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com