1 Sales Winner2000ZF intelligent wet laser particle size analyzer,Manufacturer
Position: Home > > Physical property test > Granule/powder analysis instrument > Laser particle size analyzer > Winner2000ZF intelligent wet laser particle size analyzer

Winner2000ZF intelligent wet laser particle size analyzer

Product ID:WLjg021

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberWinner2000ZF
    Brand NameYM
    Payment TermsT/T, paypal
    Product Description
    This instrument adopts comprehensive scattering light detection system with highly sensitive ring photoelectric detector improve the test accuracy greatly. Built-in cycling dispersing system avoid the sedimentation of large particle. Strong data-handling capacity and original unconstrained fitting protect accurate result with highly resolving power. Furthermore, intelligent control system developed by ourselves makes sure operation, calibration, and data processing at a full-automatic model to reduce workload of operator making flow more standardization, and minimize personal error. 
    Specifications
    Model Winner 2000ZD
    Measurement range 0.1-40μm/0.6-120μm/1-300μm
    Number of channels 32×3
    Dispersing media distilled water, alcohol and other transparent liquids
    Execution standard ISO13320,GB/T19077.1-2008,Q/JW001-2006
    Sample dispersing changeable supersonic time:1-4 minutes
    changeable stirring speed: 0-500rpm
    Accuracy <1%( standard reference material)
    reproducibility <1%( standard reference material)
    Dispersing methods ultrasonic Frequency: 40KHz, Power: 35W, Time: 0-10min
    stirring 0-300rpm
    Circulation 8L/min, 10W
    Sample chamber 350ml
    Micro sample chamber 10ml (optional)
    Operation mold Wet, full-automatic, automatic centering
    Laser He-Ne λ=632.8nm, power>2mW
    Power Source ac 220/110v          50/60hz
    Dimension 855mm×360mm×444mm
    Weight 35kg
     
    Main Features 
    Principle: Particles of different sizes scatters the illuminating laser into different patterns.
     In this instrument HeNe laser is used to illuminate and a photon detector array measures the scattered laser. 
    Software automatically converts the patterns into size distributions.
    Novel technique: It uses the Fourier transforming of converging laser to reduce the dimension of the instrument, and to obtain precise information of the scattering patterns, particularly the intensity of the 
    scattered laser at very large scattering angles. By simply changing the focal length rather than change a lens, such an optical system can easily adjust its measurement range to measure your specific 
    samples.
    Built-in dispersing system: We carefully aligned the stirring set-up, the ultrasonic
     dispersing unit and the sample circulation pipes, and fixed them inside the
     instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, 
    which can be observed in the designs that these dispersing units are separated from the
     instruments, where the sample circulation pipes are therefore too long.
    Unconstrained data fitting program: the particle analysis software uses a unique
     unconstrained data 
    fitting technique that we developed to intelligently measure an unknown size distribution, this is particularly important for material researchers, or for measuring particle size distributions with multiple peaks in data.
    Micro sample chamber: The capacity of the micro sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be 
    dispersed within medium.
    Rich software functions: Beside the basic function of analyzing the size distributions, the softwar 
    also has the following features: The output has rich content including: size distribution,
     R-R distribution, logarithmic distribution, statistics within different size ranges, volume 
    distribution, number distribution, the percentage of particles of a certain size, or a certain size range, and comparison of multiple results.
    The output could be in Word, Exce.
    Applications 
    For measurements performed on cements, ceramics ,drugs, coatings, dyes, paints, fillers, chemicals,catalysts, abrasives, lubricants, coal powder, muds and sands, dusts, cells, bacteria, foods, additives, pesticides, explosives, graphite, photosensitive materials, fuels, metal and non metal powders, calcium carbonate, kaolinite, water and coal slurry, and other powdery materials.
     

  • Product Description
    This instrument adopts comprehensive scattering light detection system with highly sensitive ring photoelectric detector improve the test accuracy greatly. Built-in cycling dispersing system avoid the sedimentation of large particle. Strong data-handling capacity and original unconstrained fitting protect accurate result with highly resolving power. Furthermore, intelligent control system developed by ourselves makes sure operation, calibration, and data processing at a full-automatic model to reduce workload of operator making flow more standardization, and minimize personal error. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com