- Model NumberWBS-100A
- Brand NameBJXQWFJS
- Payment TermsT/T, paypal
Brief introduction:
Microbial turbidimetry BS – 100A meter, 2005 edition of "pharmacopoeia of the People's Republic of China" regulation on the basis of reference USP28, BP2004, EP5.0, JP14 requirements, combined with rich practical experience and development of a new generation of microorganism titer measurement instrument, with advanced CPU 4 multivariate control management mode, the original online real-time scanning detection technology, antibiotics can be one, two, three doses were determined.
1, set constant temperature, shaking, culture and online detection and other functions as one, automatic operation;
Two sets of Latin square arrays, totaling 40 test tubes, can be placed in each incubator, and the titer of two or two groups of antibiotics can be determined simultaneously within 3-4 hours.
2. Intelligent terminal judgment ensures the accuracy of measurement results.
3. Real-time monitoring of bacterial growth and automatic drawing of bacterial growth curve.
4. The results of the titer calculation are in line with the provisions of the first, second and third dose methods in the pharmacopoeia of the People's Republic of China (2005).
5. It can output experimental reports conforming to GLP/GMP specifications, or print out the experimental results in the specified format.
6, secure and reliable instrument login and password protection measures, in line with GLP/GMP requirements on electronic signature.
7. Arrange test tubes according to the Latin square, follow the international general method, and effectively reduce the systematic error affecting the titer result.
8. Adaptive proportional integral and differential temperature control is adopted to improve the temperature control accuracy.
9, built-in ultraviolet lamp sterilization, effectively kill residual bacteria.
10. Turbidimetric method can be adopted by manufacturers to shorten testing cycle and improve productivity and efficiency.
Technical parameters:
Temperature control precision: plus or minus 0.1 ℃
Temperature uniformity: plus or minus 0.3 ℃
The heating speed: 1.5 ℃ / min
Temperature control: room temperature ~ 60 ℃
Detection cycle: 25 seconds /40 PCS
Titer calculation time: < 0.1 second
Detection accuracy: 0.001a
Repeatability: 0.001A
Repeated measurement accuracy of titer: 0.5%
Main features:
1, color LCD display, graphical interface, simple and convenient operation, easy to master;
Touch screen input, as long as the click can be completed independently complex detection process, with the convenient and flexible script board, so that Chinese and western text input becomes easier.
Multi - language platform is available for export.
2. Arrange test tubes according to the Latin square, follow the international general method, and effectively reduce the systematic error affecting the titer result.
Intelligent real-time online measurement can complete the detection of 40~400 test tubes within 25 seconds.
3. Adaptive proportional integral and differential temperature control is adopted to improve the temperature control accuracy. LED dot matrix screen prompts the current state of incubator, simple and beautiful.
4. Equipped with more powerful workstations, complete complex data transformation and image processing functions, provide sample quality tracking and management functions, effectively monitor the whole process of samples from raw materials to finished products, provide LIS interface, facilitate laboratory data sharing, and upgrade free of charge through the network.
5. Detailed experimental reports can be designed in various report formats according to different user requirements, and data or graph can be printed out in time.
6. Multiple peripheral interfaces. USB interface can be connected to U disk or mobile hard disk, storing a large number of experimental results and methods, easy to access data between different hosts.
7, non-contact rf card electronic key, provide safe and reliable instrument login and password protection measures.
8. Distributed network design, which can connect 10 incubators and conduct 20 experiments at the same time. Only one host machine can meet the needs of a large number of samples, improve work efficiency and reduce the cost of instrument procurement.