Product ID:HZYJyjq002

Price: Please inquire PDF Format
Supply Ability:120SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberHICC - S
    Brand NameYIMA
    Payment TermsT/T, paypal
    Brief introduction
    This automatic colony counter and bacteriostatic ring gauge core parameter (susceptibility titer analysis)
    The resolution of the Colonies of bacteriostatic ring 0.001 0.01 mm,

    Counter capacity: measuring 6 90 mm plate at the same time
    Counting speed: 150 ~ 800 colony forming units per second, 24 band/SEC
    Pixel: 29.6 million pixels

    Features
    1 Categories of origin
    Deep colony instrument (fifth generation) in constant should be changed, the fool a key 6 plate automatic counting: m deep HiCC - S type automatic colony counter and bacteriostasis circle measurement instrument (susceptibility analysis, titer) USES the high-resolution scanner imaging, its significant advantage is: accurate and simple.
    Application: suitable for a fully automatic colony count analysis, automatic measurement of bacteriostatic ring and antibiotic susceptibility analysis, analysis of antibiotic titer, and streptococcus titer analysis, etc

    Technical parameter
    1 imaging device:
    1) microtek ScanMaker i800 Plus double LED light source color scan imaging, up and down adjustable brightness, automatic focusing, can realize optical resolution of 29.6 million pixels homogeneous backlighting, dark field imaging and maximum color depth 48.Add 1 5 million pixels photo tablet computer
    2) to adapt to the culture dish: 50 to 180 mm and the rectangular plate inside the A4, simultaneous determination of six 90 mm AGAR (pouring, coating, membrane filter paper, spiral plate, 3 m)
    2 colony count analysis:
     1) automatic identification statistics: SmartdownTM colony intelligent recognition technology, automatic identification of mass clumps, chain adhesion of elongated coli (microscopic form large adhesion of e. coli, pathogen spores) and various colonies on AGAR (including golden staphylococcus count (GB GB4789.37-2010), determination of fecal coliform (GB/T4789.3-2010)).A key to achieve can be automatically formed batch wizard, type automatic counting
    2) automatic counting accuracy of 96.5% or higher, monitoring revised up to 3.5%, that is 100% correct. Statistical analysis speed: 150 ~ 800 colony forming units/s, large flux AGAR analysis each plate imaging with 6 + counting the total ≤ 5 seconds 
     3) colony adhesion segmentation: dividing into each other adhesion of elongated, round colonies such as the goal, the user can choose split or not. Can also be split, merge colony target image manually
    4) color shape recognition: have fast level set extraction technology, can be classified by 20 class identification number of colony count specific colors, shapes, and can convert, category, correction. Can choose six areas of automatic analysis respectively, at the same time and freedom to increase or decrease or edit analysis target zone
    5) colony morphology analysis: automatically acquire each colony area, equivalent diameter, long axis, short axis, aspect ratio, roundness, perimeter and shape factor, etc. According to the indexes filter query.
    6) the mouse to click, non-trace grid and text, automatically eliminate impurities, effective support for complex microbial statistics, the parameters of the accord with GB 47892-47892 automatic conversion features.
    3 bacteriostatic circle measurement:
    1) determination of six with a button on a 90 mm diameter AGAR all the bacteriostatic circle, can fully automatic determination of local adhesion of bacteriostatic ring, can be in local text interference, automatic result bacteriostatic circle area, diameter, etc. Measurement analysis took 1 ~ 4 seconds, unification of preservation or view the reading all kinds of analysis data
    2) plate can put any direction. Has bacteriostatic ring sample automatic selection, visual comparison of fidelity, editing functions. Bacteriostatic circle measurement system resolution error of 0.001 mm or less, repeated measurement error <0.3% ; Titer measurement error <0.3% ; Titer repeated measurement error <0.3% ;Measure the difference between <0.2%

    3) in accordance with Chinese pharmacopoeia, USP United States pharmacopoeia, European pharmacopoeia EP, can complete the latest national pharmacopoeia (2015 edition), one, two, three doses and incorporate computation, and the analysis of the all strains of antibiotic titer. Combinatorial optimization analysis feature of the effective price.
    4) according to food additives and streptococcus QB 2394-2007 standard, fully automatic measurement at the same time more than 24 bacteriostatic circle and automatic analysis of the titer
    5) built-in the CLSI "antimicrobial drug sensitivity test standards" latest edition (2015) all data, 25, convenient and update, data input and modify the susceptibility analysis provide quick tool for scraps of paper law
    5 data export: analysis results can be saved, automatic forming Excel or PDF document report. Taken the software online upgrade characteristics.
    Size five measurement functions: automatic calibration, also can be manual calibration. The mouse drag the accurate measurement of length, Angle and radian, area, arc, arbitrary curve.
    1) all deep HiCC series fully automatic colony count and bacteriostasis circle measurement analysis software, 1 set of locks and accessories
    2) ScanMaker i800 Plus double light source color scanning imager 1 and 5 million pixels photo tablets 1
    (3) lenovo all-in-one computer duo/memory/independent memory 1 g / 4 g hard disk 500 g / 23 "colorful display/wireless card, Windows XP or Windows 7) 1

     

  • Brief introduction
    This automatic colony counter and bacteriostatic ring gauge core parameter (susceptibility titer analysis)
    The resolution of the Colonies of bacteriostatic ring 0.001 0.01 mm,

    Counter capacity: measuring 6 90 mm plate at the same time
    Counting speed: 150 ~ 800 colony forming units per second, 24 band/SEC
    Pixel: 29.6 million pixels
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com