  • Model NumberUY202i
    Brand NameYIMA
    Payment TermsT/T, paypal
    Working principle
    Fluorescence is a kind of natural light emitting phenomenon. When using a beam of light substance, this substance can emit light with longer wavelength light and irradiation, the emitted light disappears. This is the longer wavelengths of light can emit fluorescence. The fluorescence substance known as fluorescent substances.
    Drop shot: the excitation light excitation principle with blue light (B light, a wavelength of 490nm) as an example, the light emitted from the DC lamp, the infrared filter and excitation filter, get the wavelength is about 490nm of the excitation light, the color spectroscope reflected into the objective, nature color spectroscope with reflection selectivity in a certain spectral region. Its characteristic is: can a certain wave length than totally reflects the light, the light of a certain wavelength longer than all through. According to this characteristic can be designed with the required excitation light color to adapt the spectroscope, making it the reflection wavelength below 490nm light. And let the light through the wavelength is greater than 490nm, this wavelength is about 490nm excitation light through color spectroscope, more than 490nm light through color spectroscope is removed, the excitation of the 490nm light through the lens assembly following fluorescence irradiates the fluorescent specimens On the specimens of the excited fluorescence wavelength is greater than 490nm (effective fluorescence wavelength is 525nm) by fluorescence imaging and color lens together, through the spectroscope (including a small amount of 490nm doping following excitation light is reflected back to the light source and not through) and filters (as all the light wavelength is less than 525nm), enter the observation and photography in the pure fluorescence beam.
    Product introduction:
    UY202i fluorescence microscopy can be widely used for gene chip, biochip, medical research, biological science, medicine and other disciplines basic theory research and clinical diagnosis, has been widely used in industry, agriculture, animal husbandry, criminal investigation, forensic identification, environmental engineering, detection and analysis of preventive medicine field.
    Working environment requirements:
    1, indoor use.
    2, ambient temperature: 0 degrees C ~ 40 degrees C
    3, the maximum relative humidity: 85%
    Technical parameter:
    This optical system: UCIS infinity independent color calibration in the optical system.
    Body: integrated design, the whole die casting, in accordance with human engineering, good vibration performance
    Magnification: 40X ~ l000X
    Eyepiece: flat field large field 10X high point eyepiece, field 20mm, high point pupil distance 21mm, diopter adjustable, with mold function.
    Objective: by the infinite flat field achromatic lens (4X/0.10 10X/0.25 40X/0.65 has mouldproof function) (spring) 100X/1.25 (spring, oil)
    Hinge: binocular viewing head 360 degrees rotation. Double pupil distance 52mm-75 mm, depending on the degree of adjustable.
    Objective: to locate the four hole conversion structure.
    This thick micro focusing device: torque adjustable workbench upper limit can be preset, coaxial focus handwheel, wheel height adjustable (patent), Lattice valued 0.001mm; coarse motion worktable adjustable, the upper limit can be preset, the maximum stroke 20mm.
    Load table: 138mm * 156mm, with a mobile ruler, moving range 76mm x 54mm, precision 0.1

  • Working principle
    Fluorescence is a kind of natural light emitting phenomenon. When using a beam of light substance, this substance can emit light with longer wavelength light and irradiation, the emitted light disappears. This is the longer wavelengths of light can emit fluorescence. The fluorescence substance known as fluorescent substances.
    Drop shot: the excitation light excitation principle with blue light (B light, a wavelength of 490nm) as an example, the light emitted from the DC lamp, the infrared filter and excitation filter, get the wavelength is about 490nm of the excitation light, the color spectroscope reflected into the objective, nature color spectroscope with reflection selectivity in a certain spectral region. Its characteristic is: can a certain wave length than totally reflects the light, the light of a certain wavelength longer than all through. According to this characteristic can be designed with the required excitation light color to adapt the spectroscope, making it the reflection wavelength below 490nm light. And let the light through the wavelength is greater than 490nm, this wavelength is about 490nm excitation light through color spectroscope, more than 490nm light through color spectroscope is removed, the excitation of the 490nm light through the lens assembly following fluorescence irradiates the fluorescent specimens On the specimens of the excited fluorescence wavelength is greater than 490nm (effective fluorescence wavelength is 525nm) by fluorescence imaging and color lens together, through the spectroscope (including a small amount of 490nm doping following excitation light is reflected back to the light source and not through) and filters (as all the light wavelength is less than 525nm), enter the observation and photography in the pure fluorescence beam.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com