Brief introduction: At present, the instrument has been widely applied in the carbohydrate, lipid, fatty acids, amino acids, drugs and polymer detection, especially traditional Chinese medicine and Chinese patent medicine without determination of ultraviolet absorption of active ingredients. Can be used with any HPLC system online; Can detect volatile below any samples of the mobile phase; Low-temperature evaporation and meet the requirements for high temperature and evaporation conditions, and at the same time to provide you with more choices; Features: 1. The optimized circuit design, reduce the instrument noise level; 2. Has a wider testing dynamic range, the same map can display a larger span of quality to the samples; 3. Effectively reduce the peak broadening, and improve the resolution; 4. The atomization mechanism tear open outfit simple and easy to clean; 5. Product volume greatly compressed, save space; Matters and make our products more professional fashion. Compact internal structure more reasonable, better reduce electromagnetic interference, more comprehensive and effective to improve the comprehensive detection performance of the product; 6. At first large size color touch-screen control ELSD, significantly improve the intelligent level of instruments and ease of use; 7. The new temperature, flow, pressure alarm function, and improve equipment stability, reliability and security. Technical indicators Power: 220 v, 50 hz Size: 460 * 330 * 330 (mm) Environmental conditions: temperature 15 to 40 ℃ relative humidity < 90% Evaporation temperature range: room temperature to 130 ℃ Temperature control increment: 1 ℃ The temperature control accuracy: + / - 1 ℃ Gas: nitrogen or air Gas input pressure range: 2 bar - 5 bar Gas pressure precision: 0.01 bar Gas flow range: 1 L/min - 4 L/min Accuracy of gas flow rate: 1%, or 0.02 L/min or less Liquid flow range: 10 mL/min L/min-3 Light source: 650 nm semiconductor laser Detection element: photo multiplier tube Baseline noise: mV <0.03 Baseline drift: mV/h <0.3 Minimum detection limit: ng <1 Typical quantitative range: 0.1 μg ~30 μg (glucose)
Brief introduction: At present, the instrument has been widely applied in the carbohydrate, lipid, fatty acids, amino acids, drugs and polymer detection, especially traditional Chinese medicine and Chinese patent medicine without determination of ultraviolet absorption of active ingredients. Can be used with any HPLC system online; Can detect volatile below any samples of the mobile phase; Low-temperature evaporation and meet the requirements for high temperature and evaporation conditions, and at the same time to provide you with more choices;