Position: Home > > Physical property test > Thickness gauge > Other thickness gauge > TIME2601 coating thickness gauge

TIME2601 coating thickness gauge

Product ID:WCHqtOther006

Price: Please inquire PDF Format
Supply Ability:350 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberTIME2601
    Brand NameBEIJINGSHIDAIZHIFENG
    Payment TermsT/T, paypal
    TIME2601 coating thickness gauge
    Introduction
    TIME2601 coating thickness gauge is a portable measuring instrument, which can quickly, without damage, and accurately measure the thickness of coating and coating. It can be used not only in the laboratory but also on the engineering site. By using different probes, it can also meet the needs of multiple measurements. This instrument conforms to the following standards: GB / T 4956─1985 Magnetic non-magnetic coating thickness measurement on magnetic metal substrate GB / T 4957─1985 Non-conductive coating thickness measurement on non-magnetic metal substrate Eddy current method JB / T 8393─1996 And eddy current coating thickness measuring instrument JJG 889─95 "Magnetic Resistance Method Thickness Gauge" JJG 818─93 "Eddy Current Thickness Gauge"
    This instrument can be widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields. It is a necessary instrument for material protection. 
    Features
    Two thickness measurement methods, magnetic and eddy current, are used to measure the thickness of the non-magnetic coating on the magnetic metal substrate and the thickness of the non-conductive coating on the non-magnetic metal substrate;
    8 kinds of probes (F400, F1, F1 / 90 °, F10, N1, CN02, F3, F5) can be used;
    There are two measurement methods: continuous measurement (CONTINUE) and single measurement (SINGLE);
    There are two working modes: direct mode (DIRECT) and group mode (A-B);
    There are five statistics: average (MEAN), maximum (MAX), minimum (MIN), number of measurements (NO.), Standard deviation (S. DEV);
    Two methods can be used to calibrate the instrument, and the basic calibration method can be used to correct the system error of the probe;
    With storage function: 640 measured values ​​can be stored;
    With delete function: delete the single suspicious data appearing in the measurement, or delete all the data in the storage area, so as to make a new measurement;
    Limits can be set: the measured values ​​outside the limits can be automatically alarmed; and a batch of measured values ​​can be analyzed with a histogram;
    With printing function: can print the measured value, statistical value, limit, histogram;
    With power supply undervoltage indication function;
    There is a buzzer prompt during the operation;
    With error prompt function, error prompt through screen display or beep;
    There are two shutdown modes: manual shutdown mode and automatic shutdown mode; 
    Technical Parameters
    Probe model F400 F1 F1/90° F10 N1 CN02  
    working principle Magnetic induction vortex  
    Measuring range (um) 0~400 0~1250 0~1250 0~10000 0~1250(Chrome plating on copper 0~40) 10~200  
    Low resolution (mm) 0.1 0.1 0.1 10 0.1 1  
    Indication One point calibration (mm) ±(3%H+1) ±(3%H+1) ±(3%H+10) ±(3%H+1.5) ±(3%H+1)  
    difference Two-point calibration (mm) ±((1~3)%H+0.7) ±((1~3)%H+1) ±((1~3)%H+1) ±((1~3)%H+10) ±[(1~3)%H+1.5]    
    Test Conditions Minimum radius of curvature (mm)
    The diameter of the smallest area (mm)
    Convex 1 1.5 Straight 10 3 Straight only  
     
    Critical thickness of substrate (mm) F3 F7 F7 F40 F5 F7  
    One point calibration (mm)
    Two-point calibration (mm)
    Minimum radius of curvature (mm)
    The diameter of the smallest area (mm)
    Critical thickness of substrate (mm)
    0.2 0.5 0.5 2 0.3 Unlimited  
     
     
  • Introduction
    TIME2601 coating thickness gauge is a portable measuring instrument, which can quickly, without damage, and accurately measure the thickness of coating and coating. It can be used not only in the laboratory but also on the engineering site. By using different probes, it can also meet the needs of multiple measurements. This instrument conforms to the following standards: GB / T 4956─1985 Magnetic non-magnetic coating thickness measurement on magnetic metal substrate GB / T 4957─1985 Non-conductive coating thickness measurement on non-magnetic metal substrate Eddy current method JB / T 8393─1996 And eddy current coating thickness measuring instrument JJG 889─95 "Magnetic Resistance Method Thickness Gauge" JJG 818─93 "Eddy Current Thickness Gauge"
    This instrument can be widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields. It is a necessary instrument for material protection. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com