SZ-C352-2P High and Low Liquid Level Automatic Controller Introduction: The SZ-C352-2P high and low level controller and SZ-Y25-V two liquid level detection heads achieve the function of liquid level high and low control: when the liquid level in the container is too low, the low liquid level alarm signal from the low liquid level sensor is triggered, which triggers the C352 controller to close the relay and start the water pump to add liquid level. When the liquid level is too low, the high liquid level sensor sends a signal to trigger the C352 controller to disconnect the relay and automatically stop the water pump from working, so the cycle works. Thus achieving the function of automatic control of container liquid level and maintaining stable container liquid level. characteristic: 1. AC180~250V wide voltage power supply 2. Relay dry node output, suitable for various load controls 3. Diversified control, can manually or automatically control the water pump 4. Easy and convenient installation, can be screw positioned for installation, and can also be installed on the track of the electrical box Technical parameters: Input voltage: AC180V-250V,50/60Hz Working current: Working current ≤ 110 mA, standby current ≤ 20mA (power consumption 0.5W) Load power: Resistive load below 1.6KW (AC contactor required for overload or three-phase load) Inductive load below 1KW (AC contactor required for overload or three-phase load) Inductive load refers to loads with inductive coils, such as motors, electromagnets, solenoid valves, and so on. Alarm output: 800W (resistive load) normally open/normally closed output Output mode: normally open/normally closed output Input signal: Low level induction signal input; High level induction signal input; Induction head interface voltage: DC 12V Working temperature: -10~75 ℃ External dimensions: 115*90*40
Introduction: The SZ-C352-2P high and low level controller and SZ-Y25-V two liquid level detection heads achieve the function of liquid level high and low control: when the liquid level in the container is too low, the low liquid level alarm signal from the low liquid level sensor is triggered, which triggers the C352 controller to close the relay and start the water pump to add liquid level. When the liquid level is too low, the high liquid level sensor sends a signal to trigger the C352 controller to disconnect the relay and automatically stop the water pump from working, so the cycle works. Thus achieving the function of automatic control of container liquid level and maintaining stable container liquid level.