1 Sales STI-1800 Sterility test isolator,Manufacturer

STI-1800 Sterility test isolator

Product ID:SHGCglq023

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberSTI-1800
    Brand NameSZHJJJKJ
    Payment TermsT/T, paypal
    Product introduction:
    STI - 1800 sterility test isolator is A physical barrier means the operating personnel in the laboratory or the powder or liquid separation in the process of production of air purification products, the isolator system can go any lower level create local grade A environment background environment, in the biological pharmaceutical industry, products and personnel is the key factor of physical isolation, and the design and application of isolator depends on the nature of the isolator using, according to the characteristics, design of the isolator, both inside and outside differential pressure, flow, construction materials, environment, type, etc.
    Working principle:
    The sterility test isolator of sti-1800 is a kind of vertical unidirectional flow air purifying equipment, which provides local classA class environment and human machine separation.
    It is widely used in the pharmaceutical industry to create A level A filling line environment in the context of A level B clean environment.
    The sterility check isolator of sti-1800 adopts the technology of physical barrier to isolate the controlled space from the external environment, and it is absolutely isolated by the safe operation of sleeve mouth.
    At the same time, vaporized hydrogen peroxide sterilization technology (VHP) is adopted to effectively kill microorganisms on the surface of articles in the airtight space and up to 6-log on the air and exposed surface in the airtight space.
    Performance parameters:
    Material: 316 stainless steel wire-drawing board
    Airtightness: the leakage rate of the cabin is no more than 5% within 10min under the pressure of 500Pa
    Wind speed: 0.35~0.65m/s, the wind speed can be adjusted, 20~60Pa should be kept during sterile operation, and the pressure should be maintained to the set value no less than 10Pa under static conditions
    Automatic residual removal efficiency: < 1PPM, 10~20min
    Cleanliness: CLASS A
    Electrical source: AC220V plus or minus 22V, 50Hz plus or minus 1Hz
    Standard inner cabin 1800*710*850
    Standard size: 1900*800*2200, customized as required
    Validation contents: sterilization efficiency: biological indicator, chemical test paper
    Class A laminar flow: wind speed, pressure difference, dust particles, plankton


     
  • Product introduction:
    STI - 1800 sterility test isolator is A physical barrier means the operating personnel in the laboratory or the powder or liquid separation in the process of production of air purification products, the isolator system can go any lower level create local grade A environment background environment, in the biological pharmaceutical industry, products and personnel is the key factor of physical isolation, and the design and application of isolator depends on the nature of the isolator using, according to the characteristics, design of the isolator, both inside and outside differential pressure, flow, construction materials, environment, type, etc.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com