Brief introduction 1.The stability of the test basis: Rise-2008 wet laser particle size analyzer using He-Ne gas laser light source, wavelength of 0.6328 micrometers, short wavelength, narrow linewidth, good stability, long service life more than 25000 hours, can be very good for the system to provide a laser source signal stability. 2.ensure reliable data: Photoelectric detection system is unique in design, high sensitivity, a main detector, a plurality of auxiliary detector, with non uniform cross three dimensional sector matrix array, maximum detection angle up to 90 degrees, and fully guarantee the overall signal detection. 3.Optical path: Using a range of unique design, a convergent path, reducing the Fu Liye lens group, the wide measurement range, high resolution, light path regulating free 4.Sample dispersion: Laser particle size analyzer ultrasonic dispersion system can be fully dispersed on the tested samples. 5.Dispersion equalization: Laser particle size analyzer by mixing and circulation continuous adjustable and fully guarantee the uniformity of dispersion. 6.Mixing system: According to the characteristics of the measured sample selection of stirring speed appropriate, to prevent the sedimentation of particles, the dispersion mixing, stirring speed fully automatic operation and touch key continuously adjustable, set the speed digital display, stirring speed 0~3000 RPM continuously adjustable, testing process and open the ultrasound can avoid mixing speed is too fast the testing error caused by air bubbles. 7.circulatory system: According to the selection of circulating pump speed appropriate properties of tested sample, to prevent the particles circulating pipeline in precipitation, circulation pump speed fully automatic operation and touch key continuously adjustable, set the speed digital display, the circulation pump speed 0~5000 RPM continuously adjustable, testing process and unlock super sound can avoid the error of the test cycle excessive speed caused by bubbles, and to prevent the particles agglomerate in the circulation process. Technical Parameters 1. Measurement range: 0.1~600 M 2. Accuracy of error: '± 1% (national standard reference material D50) 3. Repeatability error: '± 1% (national standard reference material D50) 4. Electrical requirements: 220 ± 10V, 50Hz, 200W 5. Appearance size: 1000 x 330 x 320mm 6. Weight: 38KG