- Model NumberQB2000F
- Brand NameHNCCDQ
- Payment TermsT/T, paypal
Product introduction:
QB2000F wall-mounted gas detector (hereinafter referred to as the detector) is a fixed instrument that can continuously detect the concentration of gas in the operating environment.Applicable to power, electronics, metallurgy, chemical industry, petroleum, coal, mines, railways and medicine and other occasions where gas leakage may occur.
The detector is a free diffusion method to detect the concentration of gas, using imported sensors, with excellent sensitivity and repeatability;Large LCD screen displays the concentration value of the leakage gas in real time, and immediately starts the acousto-optic alarm signal or drives the exhaust air system beyond the preset alarm point; MA signal of international standard (4~20) can be directly connected to the DCS system of the factory. RS485 digital signal is connected to the upper computer of the factory.The instrument adopts embedded micro-control technology, the whole Chinese menu operation is simple, the function is complete, the reliability is high, the entire machine performance is reliable.
The detector can be divided into explosion-proof type and non-explosion-proof type according to the application situation. Explosion-proof type: the machine did explosion-proof processing, has reached the Exd Ⅱ CT6 Gb level, can be directly connected explosion-proof bobbin, installed in the presence of the places where explosive dangerous gas and steam. Non-explosion-proof type: it is forbidden to install in the place where there is explosion risk, using plug + gasket + rubber sleeve lead.
Features:
128*64 dot matrix super large liquid crystal display
Infrared remote control function
Users can set high and low alarm points
Full Chinese menu for domestic users to use
First alarm time display function
With real-time clock function
Replaceable modular sensor
Password management function, user and manufacturer system operation separate, can effectively query the operation record
Alarm record, operation record query function
Standard 4-20)mA signal can be directly connected to the factory DCS system RS485 digital signal and connected to the upper computer of the factory (optional by users)
Technical parameters:
Processor: the instrument adopts advanced 32-bit low-power embedded micro-controller
Alarm prompt: sound, light alarm, remote alarm
Applicable gas: combustible gas, oxygen, toxic and harmful gas
Alarm point: two-level alarm, user can set;
Alarm output: two-way relay output, capacity AC 220V2A
Display error: less than or equal to 3%FS
Signal output: 4~20mA signal can be directly connected to the factory DCS system or RS485 digital signal to connect with the upper computer of the factory (optional by users)
Method of sample taking: first scatter
Working environment: - 20 ℃ + 50 ℃;
Humidity <90%RH no condensation
Operation mode: infrared remote control
Operating voltage: AC 220V 50Hz
Response time: T90<30s
Protection level: IP65
Display mode: 128*64 lattice LCD screen displays data and system status in real time
Explosion-proof grade: Exd Ⅱ CT6Gb (explosion-proof type, explosion-proof no this parameter)
Weight: about 3Kg