Position: Home > > Life science instrument and equipment > Animal experimental apparatus > Animal monitor > PM – 9000A + pet multi-parameter monitor

PM – 9000A + pet multi-parameter monitor

Product ID:SHDWjh001

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberPM-9000A+
    Brand NameYM
    Payment TermsT/T, paypal
    PM – 9000A + pet multi-parameter monitor
    Technical parameters:
    ECG
    Lead: lead all, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest guide shows
    Gain choice: x 1, 2, x 0.25 x, x 0.5 four gears
    Frequency: 0.5 Hz - 100 Hz
    Common mode signal suppression: greater than 70 db
    Scanning speed: 12.5 mm/s, 25 mm/s, 50 mm/s three standard file
    Heart rate accuracy: + / - 5 times/min
    Calibration signal: 1 mv (peak, the accuracy of + / - 3%)
    ST segment detection: measuring range (2.0 mV - + 2.0 mV)
    NIBP
    Technology: the oscillographic method
    Measurement: the reverse measure data more accurate
    The unit of measure: mmHg/Kpa
    Over voltage protection: double safety protection
    A measuring time: less than 45 s
    Cuff pressure within the range: 0-250 MMHG
    Blood pressure measurement precision: ANSI/AAMI SP10-2002 standard error of the mean and standard deviation
    Initial inflatable cuff: 180 MMHG (puppies 120 MMHG)
    Cuff subsequent inflatable: original + 30 MMHG systolic blood pressure
    SPO2 blood oxygen saturation
    Scope: 0-100%
    Accuracy: 1%
    Resolution: 1%
    Pulse rate: 20-250 times/min
    Response time: 1 s
    Warning: sound and light alarm
    Alarm range and numerical error: (more than preset alarm)
    Maximum 1% ~ 100%
    The lower limit of 0% ~ 99%
    TEMP
    Technology: high sensitive thermistor probe
    Temperature measurement range: 20 ℃ - 45 ℃
    Resolution: 0.1%
    Temperature accuracy: + / - 1 ℃
    Response time: 1 s
    Warning: sound and light alarm
    Alarm preset range and numerical error: (more than preset alarm)
    Adjustable limit between 20.1 ℃, 45.5 ℃
    Lower limit of adjustable between 20 ℃ -- 45.4 ℃
    Alarm error: + / - 1 ℃
    RESP
    Respiratory frequency range: 0-60 times/min
    Accuracy: + / - 1 RPM
    Response time: 1 s
    Gain choice: x, x, 2 x 4, 1 x 0.5 four gears
    Warning: sound and light alarm
    Alarm preset range and numerical error: (more than preset alarm)
    Adjustable limit between 10-100 times/min
    Adjustable limit between 0 and 99 times/min
    Alarm error: plus or minus 1 RPM
    system
    Display: 12.1 inch TFT true color LCD screen
    Battery (optional) : LeadAcid fully sealed and maintenance-free battery
    (international safety standards: lec601-1 GB9706.1)

     
     
  • Lead: lead all, , , , aVF, aVR, aVL, V1-6 chest guide shows
    Gain choice: x 1, 2, x 0.25 x, x 0.5 four gears
    Frequency: 0.5 Hz - 100 Hz
    Common mode signal suppression: greater than 70 db
    Scanning speed: 12.5 mm/s, 25 mm/s, 50 mm/s three standard file
    Heart rate accuracy: + / - 5 times/min

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com