Position: Home > > Physical property test > Granule/powder analysis instrument > Laser particle size analyzer > NS-90 Nanometer Particle Size Analyser

NS-90 Nanometer Particle Size Analyser

Product ID:WLjg056

Price: Please inquire PDF Format
Supply Ability:90 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberNS-90
    Brand NameZHUHAIOUMEIKE
    Payment TermsT/T, paypal
    NS-90 Nanometer Particle Size Analyser
    Introduction
    NS-90 nanoparticle size analyzer is a cost-effective characterization technology for nanoparticles. It is suitable for applications requiring high sensitivity of particle size measurement or using the same results as 90 degree scattering angle system. The instrument is suitable for the analysis of emulsion, suspension, protein and other samples.
    The instrument uses 90 degree dynamic light scattering technology to measure particle and molecular size, and static light scattering method to measure the molecular weight of protein and polymer; in many domestic brands, it is exclusively equipped with avalanche photodiode (APD) detector, which is much more sensitive than photomultiplier tube detector (PMT); it also uses high-end He-Ne gas laser, coupled with precise internal temperature control technology, and is compact. Closed-light path and advanced software algorithm ensure data repeatability, accuracy and 0.3 nanometer test lower limit; at the same time support SOP standard operation, as well as intelligent evaluation of measurement data, convenient for users to use.
    Technical Parameters
    [particle size]
    1. Measurement range: 0.3-5000 nm (subject to sample)
    2. Measurement Principle: Dynamic Light Scattering Method
    3. Detection angle: 90 degrees
    4. Repeatability error: <1%(NIST retroactive latex standard)
    5. Minimum sample volume: 20L
    6. Minimum sample concentration 0.1mg/mL (subject to sample)
    [Molecular weight]
    7. Measuring range of molecular weight: <1000 Da-2*107 Da, estimated by hydrodynamic diameter (dynamic light scattering)
    8. Measuring range of molecular weight: <10 000 Da-2 x 107 Da, calculated by Debye diagram (static light scattering)
    9. Measurement Principle: Dynamic Light Scattering, Static Light Scattering
    10. Minimum sample volume: 20 L (3-5 sample concentrations required)
    [System Hardware]
    11. Laser source: He-Ne laser with high stability, wavelength 633 nm, power 4 mW. Fifty mW, 532 nm solid-state lasers are also available.
    12. Laser safety: Category 1, meeting CDRH and CE standards
    Detector: avalanche photodiode (APD) detector, QE > 50%
    14. correlator: sampling time 25ns-8000s, 4000 channels
    15. Condensation Control: Dry Air Purge
    16. Temperature control range: 0 90 C (120 C temperature control tank is optional)
    17. Temperature Control Accuracy: +0.1 degree C
    18. Power supply: AC 100-240V, 50-60Hz
    19. Power: Maximum 100W
    [Weight and Size]
    Dimensions: 320mm *600mm *260mm (W *D *H)
    21. Weight: 21 kg
    [Operating environment]
    22. Computer configuration: Intel Core 2 Duo, 4 GB memory, 160G hard disk capacity, display resolution 1440 *900 32bit and above
    23. Computer Interface: USB 2.0
    Operating System: Windows 7 Pro (32 bit/64 bit), Windows 10 (64 bit)
    25. Temperature range: 10 C 35 C
    26. Ambient humidity: 10%-90% without condensation

     

     
  • Introduction
    NS-90 nanoparticle size analyzer is a cost-effective characterization technology for nanoparticles. It is suitable for applications requiring high sensitivity of particle size measurement or using the same results as 90 degree scattering angle system. The instrument is suitable for the analysis of emulsion, suspension, protein and other samples.
    The instrument uses 90 degree dynamic light scattering technology to measure particle and molecular size, and static light scattering method to measure the molecular weight of protein and polymer; in many domestic brands, it is exclusively equipped with avalanche photodiode (APD) detector, which is much more sensitive than photomultiplier tube detector (PMT); it also uses high-end He-Ne gas laser, coupled with precise internal temperature control technology, and is compact. Closed-light path and advanced software algorithm ensure data repeatability, accuracy and 0.3 nanometer test lower limit; at the same time support SOP standard operation, as well as intelligent evaluation of measurement data, convenient for users to use.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com