1 Model 3037 Intelligent Exhaust Gas Chloride Sampler
Position: Home > > Environmental monitoring and analysis > Air sampling equipment > Smoke / flugas sampler > Model 3037 Intelligent Exhaust Gas Chloride Sampler

Model 3037 Intelligent Exhaust Gas Chloride Sampler

Product ID:HQCYyq019

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberModel 3037
    Brand NameQINGDAOLAOYING
    Payment TermsT/T, paypal
     Model 3037 Intelligent Exhaust Gas Chloride Sampler
     
    Introduction:
        The instrument can be applied to the collection of hydrogen chloride in fixed pollution source emissions. The sampler supports two sampling modes: gas sampling and mixed state sampling. The sampling tube is equipped with full-temperature heating and temperature control. The hydrogen chloride is collected by the solution absorption method. The parameters such as flow rate, smoke temperature and moisture content can be measured at the same time.
        Products are widely used in environmental protection, testing companies, industrial and mining enterprises (power plants, steel plants, cement plants, sugar factories, paper mills, smelters, ceramics plants, boiler furnaces, and aluminum, magnesium, zinc, titanium, silicon Industry, pharmaceutical industry, including fertilizer, chemical, rubber, materials factory, etc.), health, labor, security, military, scientific research, education and other fields.
    Executive standard
      GB/T 16157-1996 Determination of particulate matter in fixed pollution source exhaust gas and sampling method of gaseous pollutants
      HJ/T 373-2007 Technical Specifications for Quality Assurance and Quality Control of Fixed Pollution Source Monitoring (Trial)
      HJ548-2016 Fixed source of waste gas Determination of hydrogen chloride Silver nitrate volumetric method
      HJ549-2016 Fixed source of waste gas Determination of hydrogen chloride Ion chromatography
    Features:
    Control system
    Unique system design, industrial high-speed embedded industrial computer core, WINCE operating system, used for the collection of hydrogen chloride in fixed pollution sources
    Accurate electronic flowmeter control, real-time monitoring of temperature, gauge, automatic flow regulation
    Real-time recording of device working status data, with sampling process power failure memory function
    With fault self-detection function, it can detect major components, main functions and faults, and is convenient for users to maintain and use.
    2. Power system
    Precision core pump, corrosion resistant, large and stable flow, continuous operation and maintenance-free, adapt to various working conditions, with overload protection
    Unique high-efficiency gas-water separator design, high-efficiency dehumidification, making silica gel utilization much higher than other similar instruments
    3. Control system
    Industrial dustproof and waterproof keyboard, easy to operate, especially suitable for harsh conditions
    5.7-inch 4H-LCD display, good human-computer interface, making work easier
    Industrial-grade connection socket, sturdy and durable, USB interface supports U disk data massive dump
    Bluetooth thermal printer for easy access to real-time data
     4. Other
    Independent sampling of flue gas and constant velocity simultaneous sampling of soot flue gas
    Dry and wet ball method moisture measurement function
    The sampling tube is made of titanium and is corrosion-resistant.
    The filter membrane and the sampling tube are heated throughout, the system automatically controls the temperature, the temperature control range is wide, and the temperature control is uniform and accurate.
    The special structure design of the incubator can realize horizontal (0~360)° rotation and vertical direction (0~90)° rotation, which can meet the requirements of various working conditions such as horizontal or vertical.
     
     
     
  • Introduction:
        The instrument can be applied to the collection of hydrogen chloride in fixed pollution source emissions. The sampler supports two sampling modes: gas sampling and mixed state sampling. The sampling tube is equipped with full-temperature heating and temperature control. The hydrogen chloride is collected by the solution absorption method. The parameters such as flow rate, smoke temperature and moisture content can be measured at the same time.
        Products are widely used in environmental protection, testing companies, industrial and mining enterprises (power plants, steel plants, cement plants, sugar factories, paper mills, smelters, ceramics plants, boiler furnaces, and aluminum, magnesium, zinc, titanium, silicon Industry, pharmaceutical industry, including fertilizer, chemical, rubber, materials factory, etc.), health, labor, security, military, scientific research, education and other fields.
    Executive standard
      GB/T 16157-1996 Determination of particulate matter in fixed pollution source exhaust gas and sampling method of gaseous pollutants
      HJ/T 373-2007 Technical Specifications for Quality Assurance and Quality Control of Fixed Pollution Source Monitoring (Trial)
      HJ548-2016 Fixed source of waste gas Determination of hydrogen chloride Silver nitrate volumetric method
      HJ549-2016 Fixed source of waste gas Determination of hydrogen chloride Ion chromatography
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com