Introduction: ATP fluorescence rapid detector can be used for the surface of medical systems and operator hands and other surface cleanliness of special equipment for rapid determination. Can also be used for surface cleanliness determination and microbial growth control. The device uses a chemical reaction to detect ATP, using an ATP swab to collect the specimen. ATP swabs are wetted by the buffer, thus helping to extract biological material (ATP) from the dry or moist surface. Swabs also contain a reagent that breaks through the biofilm, exposing any organisms that may be present under it. After specimen collection, swabs should be soaked in a volumetric container that releases intracellular ATP. The ATP released inside the cell and the ATP that the swab wipes off from the device surface then reacts with Ultrasnap's unique liquid reagent. Atp fluorescence detector for food and beverage production process control point check, medical systems and health supervision agencies real-time sampling and monitoring. Instrument features: High sensitivity - 10-15 ~ 10-18 mol Fast - conventional culture method 18-24h above, while ATP only takes ten seconds. Feasibility - There is a clear correlation between the number of microorganisms and the ATP contained in the organism. By detecting the ATP content, the number of microorganisms in the reaction can be indirectly obtained Operability - Traditional methods of training need to be performed by trained technicians in the lab, while ATP's fast cleanliness testing is easy and simple to train for on-site operations by the general staff. Technical Parameters: 1, large clear LCD screen 2, detection accuracy: 5 × 10-18mol 3, coliform bacteria: 1-106cfu 4, the detection range: 0 ~ 9999 RLUs (0 ~ 5000 fmol ATP) 5, testing time: 15 seconds 6, test interference: ± 5% or ± 5 RLUs 7, the operating temperature range: 5 ℃ to 40 ℃ 8, operating humidity range: 20-85% 9, ATP recovery rate: 90-110% 10, detection mode: RLU, coliform bacteria screening 11,50 user ID settings 12, the limit can be set the number of results: 251 13,1999 memory storage 14, automatically determine the pass 15, automatic statistics pass rate 16, built-in self-light 17, boot 30 seconds self-test 18, with RS232 interface, the results can be uploaded to the PC 19, instrument size (W × H × D): 192mm × 87mm × 34mm 20, using two standard 5 batteries or rechargeable lithium battery 21, standby (20 ℃): 6 months 22, Chinese operation manual 23, stable liquid luciferase 24, integration of wet collection swab
Introduction: ATP fluorescence rapid detector can be used for the surface of medical systems and operator hands and other surface cleanliness of special equipment for rapid determination. Can also be used for surface cleanliness determination and microbial growth control. The device uses a chemical reaction to detect ATP, using an ATP swab to collect the specimen. ATP swabs are wetted by the buffer, thus helping to extract biological material (ATP) from the dry or moist surface. Swabs also contain a reagent that breaks through the biofilm, exposing any organisms that may be present under it. After specimen collection, swabs should be soaked in a volumetric container that releases intracellular ATP. The ATP released inside the cell and the ATP that the swab wipes off from the device surface then reacts with Ultrasnap's unique liquid reagent. Atp fluorescence detector for food and beverage production process control point check, medical systems and health supervision agencies real-time sampling and monitoring.