    Features:
    1. COD/Ammonia Nitrogen/Total Phosphorus/Total Nitrogen Quick Tester, direct reading
    According to national standards
    "HJ/399-2007 Water Quality Chemical Oxygen Demand Rapid Digestion Spectrophotometry"
    "HJ/535-2009 Water Quality Determination of Ammonia Nitrogen-Nessler's Reagent Spectrophotometry"
    "GB11893/-1989 Water quality-Determination of total phosphorus-Ammonium molybdate spectrophotometric method"
    "HJ636-2012 Water Quality Determination of Total Nitrogen-Alkaline Potassium Persulfate Digestion Ultraviolet Spectrophotometry"
    2. Printing, data storage function
    Quickly print the current and stored historical data, complete the test concentration, time and other data in real time
    3. Full-wavelength spectrum scanning in the ultraviolet-visible band. Full-spectrum scanning at full wavelengths satisfies the qualitative analysis of substances; supports self-built working curves to realize quantitative analysis of substances.
    4. Data analysis platform
    The data analysis platform can achieve more precise and flexible test requirements such as spectral scanning and fixed wavelength measurement.
    5. Fully automatic intelligent spectroscopic system, shining holographic grating spectroscopy,
    6. The wavelength is automatically adjusted without manual operation.
    7. Concave blazed holographic grating
      Concave diffraction gratings are different from flat diffraction gratings. They have the advantage of being able to form a spectroscopic optical system without using imaging elements such as concave mirrors. Therefore, it should be widely used in various high-end precision analytical instruments, optical communications, biology, medical equipment and other fields.
    Technical Parameters:
    COD measurement range: 0~10000 mg/L
    Measurement range of ammonia nitrogen: 0~50 mg/L
    Measuring range of total phosphorus: 0~40 mg/L
    Measuring range of total nitrogen: 0~100 mg/L
    Transmittance accuracy: ±0.5%T
    Repeatability of transmittance: 0.2%T
    Stability: 0.001A/h
    Stray light: ≤0.05%T
    Wavelength range: 190~1000nm
    Wavelength range: 2nm
    Wavelength accuracy: ±1nm
    Wavelength repeatability: 0.2nm
    Instrument size: 480*340*210 mm
    Instrument weight: 11kg
    Working voltage: 220V±22V; 50Hz±1Hz
    Working environment: Temperature: 5~35 Humidity: ≤85%
  • Features:
    1. COD/Ammonia Nitrogen/Total Phosphorus/Total Nitrogen Quick Tester, direct reading
    According to national standards
    "HJ/399-2007 Water Quality Chemical Oxygen Demand Rapid Digestion Spectrophotometry"
    "HJ/535-2009 Water Quality Determination of Ammonia Nitrogen-Nessler's Reagent Spectrophotometry"
    "GB11893/-1989 Water quality-Determination of total phosphorus-Ammonium molybdate spectrophotometric method"
    "HJ636-2012 Water Quality Determination of Total Nitrogen-Alkaline Potassium Persulfate Digestion Ultraviolet Spectrophotometry"
    2. Printing, data storage function
    Quickly print the current and stored historical data, complete the test concentration, time and other data in real time
    3. Full-wavelength spectrum scanning in the ultraviolet-visible band. Full-spectrum scanning at full wavelengths satisfies the qualitative analysis of substances; supports self-built working curves to realize quantitative analysis of substances.
    4. Data analysis platform
    The data analysis platform can achieve more precise and flexible test requirements such as spectral scanning and fixed wavelength measurement.
    5. Fully automatic intelligent spectroscopic system, shining holographic grating spectroscopy,
    6. The wavelength is automatically adjusted without manual operation.
    7. Concave blazed holographic grating
      Concave diffraction gratings are different from flat diffraction gratings. They have the advantage of being able to form a spectroscopic optical system without using imaging elements such as concave mirrors. Therefore, it should be widely used in various high-end precision analytical instruments, optical communications, biology, medical equipment and other fields.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com