Introduction: MC-2000A -type coating thickness ( coating thickness ) measuring range : 0 ~ 1200um, is the crystallization of high-tech , which uses chip technology, high accuracy , digital display, showing the value of stable, low power consumption, easy operation no correction knob , single probe measurement of full scale , small size, light weight ; and has a store , read , statistics, low voltage indication , zero calibration , two calibration and system calibration , the performance of contemporary international advanced level of similar instruments . Features The instrument uses a magnetic thickness measurement method , you can easily non-destructive measurement on ferromagnetic material thickness of non-magnetic coating on the steel surface , such as zinc, copper, chromium plating or paint , enamel, glass, steel, rubber, paint, asphalt , etc. coating thickness. The instrument is widely used in machinery , automobile, shipbuilding, petroleum , chemical, electroplating, spray , enamel, plastics and other industries. How it works: MC-2000A -Coating Thickness Gauge uses electromagnetic induction to measure coating thickness of the coating . Of the probe element surface to produce a closed magnetic circuit with the change in the distance between the probe and the ferromagnetic material , the magnetic circuit will be different degrees of change , causing the probe coil and the reluctance change in inductance . Using this principle can precisely measure the distance between the probe and the ferromagnetic material , ie coating thickness Technical parameters 1 , measuring range : 0 ~ 1200um 2 , the measurement error : <3% ± 1um 3 , the smallest indication : 1um 4 Display: 4 digit LCD digital display 5 main functions: ( 1 ) Measurement : Single full-scale thickness measurement probe (2 ) Storage , Delete: 600 measurement data can be stored on a single measurement of suspicious data to delete, you can delete all the data stored in the region. (3 ) to read : read out stored measurement data ( 4 ) Statistics : There are three statistics , the average maximum minimum (5 ) Calibration: zero calibration can be carried out , two-point calibration and system calibration ( 6 ) power : with voltage display ( 7 ) Beeper : Beeper operation (8 ) Printing : You can print the measured values , optional mini printer (9 ) Shutdown: shutdown with automatic and manual shutdown of two ways 6, Power: two 1.5v batteries 7 , power consumption: maximum power 100mw 8 , shape every inch : 51mm * 126mm * 27mm 9 , Weight : 160g ( with battery ) 10 , the use of ambient temperature : 0 °C ~ +40 °C Relative humidity: less than 90% 11 , the matrix minimum thickness: 0.5mm 12 , the minimum diameter of the base plane : 7mm 13 , the minimum radius of curvature : Convex : 1.5mm concave : 6mm 14 , under- voltage indication : upper right corner of the display
Introduction: MC-2000A -type coating thickness ( coating thickness ) measuring range : 0 ~ 1200um, is the crystallization of high-tech , which uses chip technology, high accuracy , digital display, showing the value of stable, low power consumption, easy operation no correction knob , single probe measurement of full scale , small size, light weight ; and has a store , read , statistics, low voltage indication , zero calibration , two calibration and system calibration , the performance of contemporary international advanced level of similar instruments .