Introduction: M9000 composting biodegradation instrument can be used for biodegradability research of bio-based materials and products; it can be used for composting biodegradability testing; meeting the testing requirements of the GB/T19277.1-2011 standard; meeting the testing requirements of the ISO14855.1 standard; It can be used in other standard experiments to determine the amount of carbon dioxide released under simulated aerobic composting. Features: 1. Fully meet the testing requirements of the GB/T 19277.1 standard; 2. The design method of solid culture and open oxygen supply is adopted to simulate a strong aerobic environment; 3. High detection accuracy, 9 independent infrared detection, real-time online measurement of carbon dioxide emission; 4. Dual display of carbon dioxide concentration and cumulative amount, which can be exported in the form of graphs or curves; 5. Wide detection range, the highest detection limit can reach 10000ppm; 6. Silent design, 9 independent controllable air supply, sound less than 45db; 7. Water bath temperature control, temperature setting range is room temperature -90℃, temperature adjustment accuracy is ±0.1℃; 8. Automatic liquid level control, with automatic water replenishment design; 9. Cloud platform detection, real-time online observation of data and curves. Technical parameter: Oxygen supply system Air supply mode: continuous aeration and oxygen supply, built-in air supply pump; Number of air supply pumps: 9; Gas flow adjustment range: 2.5ml/min-25ml/min; The maximum air flow can reach 1L/min; Each channel is individually controlled, with 9 flow regulators and flow meters; Reaction system Number of channels: 9; Temperature control method: water bath type; Setting temperature range: 4-99℃, step by 0.1℃; Temperature control accuracy: ≤±0.1℃; Reaction flask volume: 2000ml; Reaction flask material: high borosilicate hard glass; Front decarburization system: Yes; Ammonia removal system: Yes; Detection Systems Detection method: infrared carbon dioxide detection; Detection range: 0-50000ppm; Detection accuracy: ±5%; Resolution: 1ppm; Detection cycle: can be used continuously for a long time. Whole machine system Power supply: 220V DC; Power frequency: 50/60Hz; Working humidity: <60%; Working temperature: 5-40℃; Machine power: 4KW; Appearance size (L×W×H): 1500mm×900mm×900mm Gross weight: 180KG.
Introduction: M9000 composting biodegradation instrument can be used for biodegradability research of bio-based materials and products; it can be used for composting biodegradability testing; meeting the testing requirements of the GB/T19277.1-2011 standard; meeting the testing requirements of the ISO14855.1 standard; It can be used in other standard experiments to determine the amount of carbon dioxide released under simulated aerobic composting.