KE2000-Y01 Medical Oxygen Quality Detection System Introduction: KE2000-Y01 medical oxygen quality detection system is a kind of medical oxygen detection standard analysis system designed specifically to meet GMP standards according to XGB2021-061 (technical indicators of medical oxygen: oxygen ≥ 99.5%, carbon monoxide<5ppm/carbon dioxide<300ppm, moisture<67ppm), Part II, Chinese Pharmacopoeia (2020). It is applicable to detection equipment for medical oxygen supervision and inspection by local food and drug regulatory authorities. This technical text clarifies the type selection, configuration and implementation scheme of the analytical instrument in the equipment, strictly complying with the index requirements of medical oxygen, the provided analytical instrument fully meets the technical specifications proposed in the instrument data sheet, and meets the integrity and design rationality of the instrument. characteristic: 1. Non dispersive infrared technology (NDIR) with independent intellectual property rights is adopted, which has the ability to detect ultra-low gas concentration; 2. Based on the technical design, the sensor probe provides true dual wavelength infrared detection to obtain low drift, high-precision measurement results with fast response time and low power consumption; 3. The infrared light source with stable performance extends the service life and reduces the impact of shock and vibration; 4. The system uses a 15 inch color screen, USB storage and input, and reports can be printed directly 5. Modular design, light source, detector, core circuit, gas chamber, etc. adopt modular design, with high reliability, good scalability and convenient maintenance; 6. Independent gas detection module, easy to integrate into any detection system or control system; 7. The dense flow dual detector with high induction and reliability adopts the protection block of infrared radiation mode to compensate the absorption signal of the measured gas. Compared with the single channel scheme, the measurement is less affected by external environmental factors, and the results are more stable, so frequent calibration is not required; 8. Output signal: RS232 or RS485; 9. CO and CO2 are displayed at the same time to meet customer needs, and it is convenient for direct management; 10. When the data deviates from the alarm value, the system outputs the alarm signal, and the alarm value can be set freely within the range; 11. Isolated analog current output, which can be calibrated online; 12. Meet the requirements of XGB2021-61, Part II of Chinese Pharmacopoeia in 2020. Technical parameters: System detection parameters and measuring range: Carbon dioxide: 0~500PPm CO2 Carbon monoxide: 0 ~ 50ppm CO (range optional) Dew point: 0 ~ 500ppm H2O Oxygen: 80% ~ Zero drift: ≤± 1% FS/7d Range drift: ≤± 1% FS/7d Repeatability: ≤± 0.5% F. S Load: ≤ 750 Ω Output signal: 4 ~ 20 mA DC Table instrument size: 483mm * 179mm * 380 Boundary dimension of cabinet: 600mm * 600mm * 1800mm Applicable medium: medical oxygen Gas sample temperature: normal temperature Gas sample pressure range: 0.1~15MPa Power supply: AC: 220V
Introduction: KE2000-Y01 medical oxygen quality detection system is a kind of medical oxygen detection standard analysis system designed specifically to meet GMP standards according to XGB2021-061 (technical indicators of medical oxygen: oxygen ≥ 99.5%, carbon monoxide<5ppm/carbon dioxide<300ppm, moisture<67ppm), Part II, Chinese Pharmacopoeia (2020). It is applicable to detection equipment for medical oxygen supervision and inspection by local food and drug regulatory authorities. This technical text clarifies the type selection, configuration and implementation scheme of the analytical instrument in the equipment, strictly complying with the index requirements of medical oxygen, the provided analytical instrument fully meets the technical specifications proposed in the instrument data sheet, and meets the integrity and design rationality of the instrument.