LC3000-PCD post-column derivatization analysis system Introduction
The advanced pump drive system makes the pump performance better, higher precision and better stability. With high-efficiency electronic pulsation suppression technology, the pulsation is reduced to a minimum, and the wavelength accuracy and stability of the UV detector are also greatly improved. . This allows the system to meet the needs of most advanced users. The dual pump system can achieve both gradient and isocratic operations, giving operators more options. Features
The gradient is easy to adjust;
Modular units are easy to combine;
Positive and negative switching is free;
A bioanalytical compatible system is available. Technical Parameters
P3000N high pressure infusion pump
Flow range: (0 ~ 10.000) mL / min
Maximum working pressure: 42MPa
Flow accuracy: ±0.5% (1mL/min)
Flow repeatability: RSD ≤ 0.1% (1mL / min)
Power supply: 220V ± 22V, 50Hz, 120W
Dimensions and weight: 450 × 270 × 180mm (length × width × height) 12.8kg
UV3000N UV-Vis Spectroscopic Detector
Wavelength range: (190 ~ 800) nm
Light source: xenon lamp (standard configuration); tungsten lamp (replaceable)
Band width: 8nm Wavelength accuracy: ±2nm Wavelength repeatability: 0.4nm
Baseline noise: 1.5×10-5AU/h
Dynamic: flow rate 1mL / min; methanol, wavelength 254nm
Baseline drift: 4 × 10 -4 AU / h
Dynamic: flow rate 1mL / min; methanol, wavelength 254nm
Detection tank volume: 10uL
Power supply: 220V ± 22V, 50Hz, 150W
Dimensions and weight: 450 × 270 × 180mm (length × width × height) 10.4kg
gradient
Gradient error limit ± 2%
Gradient repeatability deviation limit <1%
Reagent pump
Flow range: (0 ~ 9.999) mL / min
Maximum working pressure: 42MPa
Flow accuracy: ±0.5%
Flow repeatability: RSD ≤ 0.1%
Pump head material: 316L
Power supply: 220V ± 22V, 50Hz, 200W
Dimensions and weight: 450 × 270 × 180mm (length × width × height) 13.6kg
reactor
Heating reactor accuracy: ±0.4 °C
Room temperature to 150 ° C
Reaction volume varies by application
Reaction coil can withstand pressure 40MPa
LCD displays actual temperature or set temperature
Temperature protection 150 ° C
Introduction
The advanced pump drive system makes the pump performance better, higher precision and better stability. With high-efficiency electronic pulsation suppression technology, the pulsation is reduced to a minimum, and the wavelength accuracy and stability of the UV detector are also greatly improved. . This allows the system to meet the needs of most advanced users. The dual pump system can achieve both gradient and isocratic operations, giving operators more options.