1 Sales LC-600 Quaternary Low Pressure Liquid Chromatograph,Manufacturer
Position: Home > > Analytical instruments > Chromatogram > Liquid chromatography > LC-600 Quaternary Low Pressure Liquid Chromatograph

LC-600 Quaternary Low Pressure Liquid Chromatograph

Product ID:FSye025

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberLC-600
    Brand NameNANJINGKEJIE
    Payment TermsT/T, paypal
    LC-600 Quaternary Low Pressure Liquid Chromatograph
     
    Introduction:
     The LC-600B intelligent full-control liquid chromatography system directly consists of two P600B high-pressure constant current pumps, one UV600B ultraviolet detector and one SCL600B system controller. The infusion pump uses a plunger floating installation to enhance the stability of the instrument's performance and durability.
    Application: It can be widely used in many analytical fields such as research and development, medical inspection, food testing, chemical analysis, environmental monitoring and so on.
    Features:
    1. Rich features - in line with the different needs of customers for analysis
    The hardware has VP function, records maintenance information and operation records, and meets GLP/GMP requirements; the system controller has the functions of humanized design such as clock, thermometer and hygrometer.
    2. Excellent performance - to meet the strict requirements of customers on the instrument
    (1) The infusion pump adopts a plunger made of material structure, an enhanced Teflon seal ring, and a plunger floating installation method to enhance the stability of the performance of the instrument and the durability of use.
    (2) The detector adopts double-beam monochromator consisting of imported xenon lamp, photocell and 1200/mm concave grating, precision-processed double-lens flow cell, high-precision microprocessor for controlling wavelength adjustment, and high-speed sampling frequency of two channels. It ensures low noise, low drift and high sensitivity.
    (3) The mixer is evenly mixed, and the baseline collected using the gradient program maintains good reproducibility.
     3. Reliable results - meeting customer's exact requirements for results
      Compared with imported instruments, the results are highly consistent.
    4. Easy operation - easy for customers to master the software
    The software adopts multi-window mode and is easy to operate.
    5. Exquisite appearance - to meet the customer's visual requirements for the instrument
    Beautifully presented for a visual enjoyment.
    6. A variety of user software - to meet the needs of different users
    The LC600B isocratic high performance liquid chromatograph dedicated chromatographic data workstation is embedded in the detector. There are three sets of VI5890, N2000 and N3000 for customers to use selectively to meet the needs of different users.
     Technical parameter:
    LC600B high pressure constant flow infusion pump
    Infusion method: micro volume series double plunger
    Zui large infusion pressure: 0 ~ 9999Psi
    Flow setting range: 0.00~9.999mL/min (adjust flow rate in steps of 0.001mL/min)
    Flow set value error: ≤0.5%
    Flow stability error: ≤0.2%RSD
    Gradient error: ±1% (0-100% water/acetic acid aqueous solution 2 liquid gradient)
    Pressure pulsation: less than 15Psi (flow rate 1mL / min, pressure 600 ~ 1600Psi)
    Pump tightness: pressure is 5400Psi, time is 10min, pressure drop is less than 400Psi
    Time program function: Yes
    Size: W260×H130×D420mm
    Weight: 11kg
    Operating ambient temperature range: 4 ~ 40 ° C
    SPD600B UV-Visible Variable Wavelength Detector
    Wavelength range: 190nm ~ 700nm
    Wavelength indication error: ≤±1nm
    Wavelength repeatability error: ≤±0.1nm
    Dynamic noise: ≤ ±0.75×10-5AU (methanol, 1ml/min, 254nm, 20°C)
    Static noise: ≤ ±0.5×10-5 AU (empty pool, response time 1 second, 20 °C)
    Dynamic baseline drift: ≤ ± 1 × 10 -4 AU / h (methanol, 1 mL / min, 254 nm, 20 ° C)
    Static baseline drift: ≤ 5 × 10 -4 AU / h (empty pool, response time 1 second, 20 ° C)
    Linear range: ≥104
    Zii small detection concentration: ≤ 1 × 10-9g / mL (naphthalene / methanol solution)
    Qualitative repeatability: RSD6 ≤ 0.1%
    Quantitative repeatability: RSD6 ≤ 0.5%
    Spectral bandwidth: 6nm
    Flow cell volume: 8μL
    Optical path: 10mm
    Time program function: Yes
    Size: W260×H130×D420mm
    Weight: 11kg
    Operating ambient temperature range: 4 ~ 40 ° C
     
  • Introduction:
     The LC-600B intelligent full-control liquid chromatography system directly consists of two P600B high-pressure constant current pumps, one UV600B ultraviolet detector and one SCL600B system controller. The infusion pump uses a plunger floating installation to enhance the stability of the instrument's performance and durability.
    Application: It can be widely used in many analytical fields such as research and development, medical inspection, food testing, chemical analysis, environmental monitoring and so on.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com