Introduction: K3800 high press pump can be assembled into several systems based on client’s needs, including equal gradient analysis, equal gradient semi-preparation, high pressure gradient analysis, high pressure gradient semi-preparation, low pressure gradient analysis, low pressure gradient semi-preparation, and so on. It’s suitable to analyze the synthetic and natural compounds which are related to petroleum chemical industry, food, synthetic medicine, biochemical products and environmental pollutant, etc. The K3800 HPLC is mainly applied in the departments of examination of medicine, chemical industry, environmental protection, sanitation, as well as colleges, universities and research institutions which engaged in scientific research activities of analytical chemistry, biochemistry, environmental industry, etc. Performance index K3800 detector Wavelength rang: 190-740nm Light source: deuterium lamp(standard), tungsten lamp(option) Baseline noise: 1.5×10-5Abs Baseline drift: 1×10-4Abs/h Wavelength precision: ±1nm Wavelength repeatability: 0.4nm Detection limit: ≤4×10-8g/ml(methanol solution of naphthlene) Detection range: 0-2Abs Flow cell volume: 10μl Signal output: ±2.0V divided into 16 steps, adjustable; K3800 High pressure pump Flux range: 0.001~9.999ml/min Maximum working pressure: 42MPa Flux precision: ±0.5% Flux repeatability: RSD≤ 0.1% Gradient precision: ±1% Gradient repeatability: ±0.5% Features Self-check when starting; Convenient to replace the pump head and flow cell; High pressure pump: pressure pulsation are controlled through electron; Flux, max press, min press, flux correction parameter, instrument serial number and total run time can be set Max press and min press protection; All parameters can be controlled by computer through workstation; K3800 can be controlled by computer, high pressure grads module, several sets of LC can communicate in series; Automatic zero adjustment. Normal working conditions Environment temperature: 10-35°C Environment humidity: ≤80% Power supply: 220V±22V,50Hz±0.5Hz
Introduction: K3800 high press pump can be assembled into several systems based on client’s needs, including equal gradient analysis, equal gradient semi-preparation, high pressure gradient analysis, high pressure gradient semi-preparation, low pressure gradient analysis, low pressure gradient semi-preparation, and so on. It’s suitable to analyze the synthetic and natural compounds which are related to petroleum chemical industry, food, synthetic medicine, biochemical products and environmental pollutant, etc. The K3800 HPLC is mainly applied in the departments of examination of medicine, chemical industry, environmental protection, sanitation, as well as colleges, universities and research institutions which engaged in scientific research activities of analytical chemistry, biochemistry, environmental industry, etc.