Summary: This instrument is a primary instrument for precipitation measurement, and its performance conforms to the national standard GB/ t11832-2002 "tipping bucket rain gauge" requirements. This instrument adopts the national invention patent, and a two-way flip plate is set on the top of the tumbler, which greatly reduces the switching time of the tumbler precipitation, thus reducing the measuring error of the instrument to the leading level of less than or equal to 1%, and making the performance of the instrument more stable. This instrument belongs to the high sensitivity, high precision precision rainfall sensor, the use of the process of the instrument must be regularly cleaned, maintained and tested, otherwise the instrument may be out of alignment, failure. The tilting Angle of the tilting bucket has been adjusted and locked in the optimal tilting Angle position when the instrument leaves the factory. When installing the instrument, it is only necessary to adjust the base level according to the requirements of this manual before putting it into use. It is not allowed to adjust the tilting Angle adjustment screw on the spot. The inner wall of the tipper of this instrument has been specially hydrophilic treatment. Do not touch or scratch the coating of the inner wall of the tipper with your fingers in the process of installing and cleaning the instrument. Main technical parameters: 1.Diameter of bearing rain: φ 20000.60 mm, acute angle of cutting edge: 40 °~ 45 ° 2. Resolution: 0.1mm 3. Range of rain intensity: 0.01mm~4mm/min 4. Accuracy of measurement: ≤±2% (in accordance with National Standard I accuracy requirement) ≤±1% (excellent grade, accuracy is superior to National Standard I accuracy standard) 5. Mode of transmission: two channels of dry spring tube, break signal output 6. Working environment: ambient temperature: -10 ℃ ~ 50 ℃ relative humidity; < 95% (40 ℃) 7. Size: φ 216mm × 470mm 8. Weight: 3.1Kg
Summary: This instrument is a primary instrument for precipitation measurement, and its performance conforms to the national standard GB/ t11832-2002 "tipping bucket rain gauge" requirements. This instrument adopts the national invention patent, and a two-way flip plate is set on the top of the tumbler, which greatly reduces the switching time of the tumbler precipitation, thus reducing the measuring error of the instrument to the leading level of less than or equal to 1%, and making the performance of the instrument more stable. This instrument belongs to the high sensitivity, high precision precision rainfall sensor, the use of the process of the instrument must be regularly cleaned, maintained and tested, otherwise the instrument may be out of alignment, failure. The tilting Angle of the tilting bucket has been adjusted and locked in the optimal tilting Angle position when the instrument leaves the factory. When installing the instrument, it is only necessary to adjust the base level according to the requirements of this manual before putting it into use. It is not allowed to adjust the tilting Angle adjustment screw on the spot. The inner wall of the tipper of this instrument has been specially hydrophilic treatment. Do not touch or scratch the coating of the inner wall of the tipper with your fingers in the process of installing and cleaning the instrument.