ISO-C Aseptic Isolation System Introduction: ISO-C single compartment sterile inspection isolator can be customized according to requirements for inspection or production. Suitable for sterile rooms, microbial limit testing rooms, or positive rooms in pharmaceutical companies. A sterile room, microbial limit testing room, or positive room used for drug testing systems. Suitable for sterile rooms, microbial limit testing rooms, or positive rooms of medical device enterprises. Suitable for hospital preparation rooms. Suitable for microbiological testing of highly toxic and highly allergenic drugs. Suitable for microbiological testing of biological products, etc. characteristic: 1. Adopting the new generation of hydrogen peroxide iVik cold evaporation technology from Vico Biotech, the dual chamber sterilization cycle can be completed in 60 minutes, and the transfer window sterilization cycle can be completed in 30 minutes 2. Sterilization efficiency can reduce the growth rate of Bacillus subtilis by 6 logs 3. Use hydrogen peroxide sporicidal agent with a concentration of ≤ 8%, which is non hazardous and non explosive, and does not require public security registration. 4. During the sterilization cycle of the cabin, there is no temperature rise to meet the requirement of biological products not being heated. 5. It can be directly discharged indoors, and the inlet and outlet air of the cabin does not affect the air volume of the placement room. (Optional) 6. Equipped with dual dehumidification functions of desiccant and compressed air to meet any customer's requirements. 7. Equipped with automatic information reading function for disinfectants, expiration alarm function for disinfectants, and complete sterilization report. Technical parameters: Power supply: AC220V ± 22V/50Hz Power: 2500VA Dimensions: Customized Noise: ≤ 75dB(A) Work pressure:- 80-80Pa (adjustable) Cleanliness: Grade A Airflow model: laminar flow in the control cabin and laminar flow in the transfer window Killing rate: Thermophilic Bacillus subtilis decreased by 6 log Hydrogen peroxide: 30% -50% hydrogen peroxide solution Hydrogen peroxide concentration during sterilization: 100-200PPM Touch screen: Siemens touch screen/12 inch tablet computer Control: Siemens PLC Leakage rate: ≤ 0.5%vol/h Illumination:> 300LX Leakage rate: ≤ 0.5%vol/h High efficiency filter: H14 (Confel) VHP sterilization cycle time: Operation cabin: ≤ 60 minutes Cabin temperature rise degree: no temperature rise
Introduction: ISO-C single compartment sterile inspection isolator can be customized according to requirements for inspection or production. Suitable for sterile rooms, microbial limit testing rooms, or positive rooms in pharmaceutical companies. A sterile room, microbial limit testing room, or positive room used for drug testing systems. Suitable for sterile rooms, microbial limit testing rooms, or positive rooms of medical device enterprises. Suitable for hospital preparation rooms. Suitable for microbiological testing of highly toxic and highly allergenic drugs. Suitable for microbiological testing of biological products, etc.