Brief introduction:
ICP2060T inductively coupled plasma emission spectrometer is especially suitable for determination of constants in all kinds of petrochemical products, trace, and the content of trace elements. Instruments have professional perfect oil directly into the sample measurement technology, can adjust oxygen flow intelligent elimination of the influence of carbon deposition, high efficiency, strong anti-interference, high degree of automation, simple operation, stable and reliable, wide range of testing, fast analysis speed, low detection limit, etc Features:
1. The advanced oil directly into the sample measurement technology
2. Intelligent regulating oxygen flow, eliminate carbon deposition
3. More than 70 kinds of measurable elements
4. The analysis speed, measurable 5-8 elements in a minute
5. Multielement analysis at the same time, customers can choose elements number and arrange measuring order
6. Low detection limit, can achieve PPB level
7. Wide linear dynamic range, up to 6 orders of magnitude, high and low levels can be measured at the same time
8. Analysis of the cost is low, a bottle of argon gas can use 10 to 12 hours
9. Argon gas consumption is low
10. Wide wavelength range
11. A fully automated design
12. Performance enhancement organic sample system
13. Gas flow automatic control
14. Stable and advanced solid-state rf power supply
15. Fast automatic matching function
16. Stable performance of the optical system Technical indicators:
Volume: desktop, on the desktop, 1.5 m * 0.8 m * 0.8 m
Solid state power
Operating frequency: 27.12 MHz
Frequency stability: < 0.05%
Matching: match automatically
Output power: 800 w ~ 1600 w, continuous adjustable, power efficiency is more than 65%
The output power stability: 0.2% or less
Scanning the beam splitter
Light path: Czerny Turner
Focal length: 1000 mm
Holographic grating, grating specifications: ion etching groove density l/l / 3600 mm or 3600 mm; Score area (80 x 110 mm
Resolution: 0.008 nm or less (3600 line grating) 0.015 nm or less (2400 line grating)
Scanning wavelength range: 3600 line grating (190 ~ 500 nm); 2400 line grating: (190 ~ 800 nm)
Electronic measurement and control circuit
Photomultiplier tube specifications: R212 / R928
Photomultiplier tube negative high voltage (V ~ 50-1000)
Photomultiplier current measuring range: 10-12 ~ 10-4) A
Signal acquisition: VF transformation
The whole machine technical indicators
Scanning wavelength range: 190 nm to 500 nm (3600 l/mm grating), 190 nm to 800 nm (2400 l/mm grating)
Measuring range
Content: 0.01 parts per million - thousands of PPM.
Repeatability: the short-term stability) relative standard deviation RSD 1.5% or less;
Stability: the relative standard deviation RSD 2% or less;
The test speed: 5-8 elements/per minute
Brief introduction:
ICP2060T inductively coupled plasma emission spectrometer is especially suitable for determination of constants in all kinds of petrochemical products, trace, and the content of trace elements. Instruments have professional perfect oil directly into the sample measurement technology, can adjust oxygen flow intelligent elimination of the influence of carbon deposition, high efficiency, strong anti-interference, high degree of automation, simple operation, stable and reliable, wide range of testing, fast analysis speed, low detection limit, etc